My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2375
>
2300 - Underground Storage Tank Program
>
PR0232469
>
COMPLIANCE INFO_2008-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2021 2:40:22 PM
Creation date
6/23/2020 6:56:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2011
RECORD_ID
PR0232469
PE
2361
FACILITY_ID
FA0003772
FACILITY_NAME
GRANT LINE SHELL*
STREET_NUMBER
2375
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21402017
CURRENT_STATUS
01
SITE_LOCATION
2375 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\2375\PR0232469\FINAL JUDGMENT 11-06-09.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
564
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JUN-20-2011 07:43 Service Station Systems 408 938 8888 P.08 <br /> S. PIPING SUMP TESTING <br /> Test Method Developed By: O Sump Manufacturer ® industry Standard p Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: O Pressure Q Vacuum 0 Hydrostatic <br /> ©Other(Spec) <br /> Test Equipment Used: Incon Sump Tester Equipment Resolution: +/-0.002" <br /> OOR 111=1101111111 <br /> STP Sump#87 B STP Sump#84 B STP Sump#91 B <br /> Sump Diameter: 42" 42" 42" <br /> Sump Depth: 83" 83" 83" <br /> Sump Material: Fiberglass Fiberglass Fiberglass <br /> Height from Tank Top to Top of 15" 15" 15" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 26" 26" 26" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Good Good Good <br /> Portion of Sump Tested` 2"above piping 2"above piping 2"above piping <br /> Does turbine shut down when <br /> sump sensor detects liquid(both O Yes A No ®NA O Yes❑No RNA ❑Yes O No RNA <br /> product and water)f <br /> Turbine shutdown response time N/A N/A N/A <br /> Is system programmed for fail-safe O Yes❑No ®NA O Yos O No RNA O Yes O No NNA <br /> shutdown?* <br /> Was fail-safe verified to be ❑Yes®No ®NA q Yes❑No RNA O Yes❑No RNA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 30 minutes 30 minutes 30 minutes <br /> test: <br /> Test Start Time: <br /> initial Reading(RI): <br /> Test End Time: <br /> Final Reading(RF): <br /> Test Duration: <br /> Change in Reading(RF-Ri): <br /> Pass/Fail Threshold or Criteria: <br /> Test Result: 0 Pass Q Fail ❑ Pass ® Fail ❑ Pass ® Fail <br /> Was sensor removed for testing? Oyes O No M NA OYes p No 10 NA ❑Yes O No®NA <br /> Was sensor properly replaced and OYes O No® NA Oyes O No C9 NA ❑Yes O No R NA <br /> verified functional after testin - <br /> Comments—(include information on repairs made prior to testing, and recommended follow-u or failed tests) <br /> "Sensor functionality was not confirmed.This procedure is not part of the Secondary Containment testing scope of work". <br /> Unable to test 87 B,89 B and 91 B,due to torn test boots <br /> ' if the entire depth of the sump is not tested,specify how much was tested. if the answer to oLny of the questions indicated with an <br /> asterisk(*)is"NO,*or"NA",the entire sump most be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.