My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2375
>
2300 - Underground Storage Tank Program
>
PR0232469
>
COMPLIANCE INFO_2008-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2021 2:40:22 PM
Creation date
6/23/2020 6:56:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2011
RECORD_ID
PR0232469
PE
2361
FACILITY_ID
FA0003772
FACILITY_NAME
GRANT LINE SHELL*
STREET_NUMBER
2375
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21402017
CURRENT_STATUS
01
SITE_LOCATION
2375 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\2375\PR0232469\FINAL JUDGMENT 11-06-09.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
564
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JUN-20-2011 07:44 Service Station Systems 408 938 8888 P.10 <br /> 10. UNDER-DISPENSER CONTAINMENT UDC TESTING <br /> Test Method Developed By: L7 UDC Manufacturer ®industry Standard ❑ Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used: ❑Pressure ❑ Vacuum ®Hydrostatic <br /> ❑ Other(Npecify) <br /> Test Equipment Used: Ineon Sump Tester Equipment Resolution_ +/-0.002" <br /> )C#9/10 UDC#11/12 UDC# 13/14 UDC#15/16 <br /> UDC Manufacturer: OPW OPW OPW OPW <br /> UDC Material: Plastic Plastic Plastic Plastic <br /> UDC the 31" 31" 31" 31" <br /> Height from UDC Bottom to Top 16" 16" 16" 16" <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 81, 8++ 8" 8" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Good Good Good Good <br /> testing: <br /> Portion of UDC Tested 2"abovei in 2"above pi in 2"above piping 2"above pipmg <br /> Does turbine shut down when <br /> UDC sensor detectsliquid(both C]Yes[3 No ®NA L7 Yes❑No RNA p Yes Q No NNA ❑Yes C]No ®NA <br /> product and water)?� <br /> Turbine shutdown response time N/A N/A N/A N/A <br /> Is system programmed for fait- ©Yes 0 No ®NA Q Yes❑No RNA [3 Yes❑No RNA [3 Yes©No RNA <br /> safe shutdown?` <br /> Was fail-safe verified to be Q Yes❑No M NA ❑Yes p No ONA D Yes❑No RNA Q Yes 0 No RNA <br /> o erationalf <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes 30 minutes <br /> -starting test <br /> Test Start Time: 11:22 am l:OS m 2:56 m 11:22 am <br /> Initial Reading R,): 4.6327 3.5354 3.0650 3.5486 <br /> Test End Time: 11,37 am 1:20 prn 3:11 pra 11:37 am <br /> Final Reading(RF): 4.6323 3.5371 3.0650 3.5489 <br /> Test Duration: 15 min. 15 min. 15 min. 15 min. <br /> Change in Reading(RF-RI), -0.0004 +0.0017 None +0.0003 <br /> Pass/Fail Threshold or Criteria: +/-0.002" +/-0.002" +/-0.002" +/-0,002" <br /> Test Result: ® Pass U Pail M Pass D Fail ® Pass ©Fail ® Pass a Fail <br /> Was sensor removed for testin ? ®Yes❑No Q NA M Yes❑No 0 NA O Yes❑No❑NA M Yes Q No O NA <br /> Was sensor properly replaced and ®yes❑No❑NA Yes C]No❑NA ®Yes Q No[�NA ®Yes p No Q'NA <br /> verified functional after testin ? <br /> Comments—(include information on repairs made prior to testing and recommendedfollow-up forfailed tests) <br /> "Sensor functionality was not confirmed.This procedure is not part of the Secondary Containment testing scope of work". <br /> ' If the entire depth of the UDC is not tested,specify how much was tested. If the answer to ay of the questions indicated with an <br /> asterisk(*)is"NO"or'INA",the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.