My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2375
>
2300 - Underground Storage Tank Program
>
PR0232469
>
COMPLIANCE INFO_2012-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2021 4:12:21 PM
Creation date
6/23/2020 6:56:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2017
RECORD_ID
PR0232469
PE
2361
FACILITY_ID
FA0003772
FACILITY_NAME
GRANT LINE SHELL*
STREET_NUMBER
2375
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21402017
CURRENT_STATUS
01
SITE_LOCATION
2375 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232469_2375 W GRANT LINE_2012-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
447
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7. UNDER -DISPENSER CONTAINMENT (UDC) TESTING <br />Test Method Developed By: ❑ UDC Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Incon Sump <br />Tester Equipment Resolution: +/- 0.002" <br />r <br />UDC # 1/2 UDC # 3/4 UDC # 5/6 UDC # 7/8 x <br />UDC Manufacturer: <br />OPW OPW OPW OPW <br />UDC Material: <br />Fiberglass Fiberglass <br />Fiberglass <br />Fiberglass <br />UDC Depth: <br />31" 31" <br />31" <br />31" <br />Height from UDC Bottom to Top <br />21„ 22" <br />21" <br />20" <br />of Highest Pi ,in Penetration: <br />Height from UDC Bottom to <br />6" 6" <br />8" <br />8" <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />Good Good <br />Good <br />Good <br />testing: <br />Portion of UDC Tested <br />2" above piping 2" above piping <br />2" above piping <br />2" above piping <br />Does turbine shut down when <br />F <br />UDC sensor detects liquid (both <br />❑ Yes ❑ No ® NA ❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />product and water)?* <br />' <br />Turbine shutdown response time <br />N/A N/A <br />N/A <br />N/A <br />Is system programmed for fail- <br />❑ Yes ❑ No ® NA ❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />safe shutdown?` <br />Was fail-safe verified to be <br />❑ Yes ❑ No ® NA ❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />operational?* <br />Wait time between applying <br />pressure/vacuum/water and <br />30 minutes 30 minutes <br />30 minutes <br />30 minutes <br />starting : test <br />Test Start Time: <br />4:11 pin 4:11 pm <br />1:04 pm <br />4:11 pm <br />Initial Reading (Ri): <br />2.6825 0.1979 <br />3.4624 <br />7.2177 <br />Test End Time: <br />4:26 pm 4:26 pm <br />1:19 pm <br />4:27 pm <br />Final Reading (RF): <br />2.6527 1.5836 <br />3.4624 <br />7.2178 <br />Test Duration: <br />15 min. 15 min. <br />15 min. <br />16 min. <br />Change in Reading (RF -RI): <br />0.0298 1.7815 <br />None <br />0.0001 <br />Pass/Fail Threshold or Criteria: <br />+/-0.002" +/- 0.002" <br />+/- 0.002" <br />+/-0.002" <br />Test Result: <br />❑ Pass El Fail ❑ Pass El Fail <br />® Pass ❑ Fail <br />M Pass ❑ Fail <br />Was sensor removed for testing? <br />® Yes ❑ No ❑ NA ® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />® Yes ElNo ❑ NA ® Yes ElNo ❑ NA <br />N Yes ❑ No ❑ NA <br />® Yes ❑ No ElNA <br />5 <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />"Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work". <br />1/2 & 3/4, Failed due to torn penetration conduits. <br />a <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk(*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.