My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1992-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
121
>
2300 - Underground Storage Tank Program
>
PR0232594
>
COMPLIANCE INFO_1992-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2024 12:53:22 PM
Creation date
6/23/2020 6:56:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1992-2005
RECORD_ID
PR0232594
PE
2361
FACILITY_ID
FA0004573
FACILITY_NAME
SJ COUNTY PARKING GARAGE
STREET_NUMBER
121
Direction
S
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
14912001
CURRENT_STATUS
01
SITE_LOCATION
121 S SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232594_121 S SAN JOAQUIN_1992-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
428
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB. January 2002 <br />4. TANK ANNULAR TESTING <br />Page 2 of 7 <br />Test Method Developed By: [ X ] Tank Manufacturer [ ] Industry Standard [ ] Professional Engineer <br />[ ] Other (Specify) <br />Test Method Used: [ ] Pressure [ X ] Vacuum [ ] Hydrostatic <br />[ ] Other (Specify) <br />Test Equipment Used: Equipment Resolution: <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />XERXES TEST THRESHOLD STATES, IT CAN NOT DROP BELOW 8 INCHES Hg IN ONE HOUR <br />1 Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary containment, such as systems <br />that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment testing. (California Code of Regulations, Title 23, <br />Section 2637(a)(6)) <br />Tank #1 <br />Tank # <br />Tank # <br />Tank # <br />Is Tank Exempt From T-esting? 1 <br />[ ] Yes [ X ] No <br />[ ] Yes [ ] No <br />[ ] Yes [ ] <br />No <br />[ ] Yes [ ] No <br />Tank Capacity: <br />10,000 GALLON <br />Tank Material: <br />FIBERGLASS <br />Tank Manufacturer: <br />XERXES <br />Product Stored: <br />UNLEAD <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />10 MINUTES <br />Test Start Time: <br />9:30 A.M. <br />Initial Reading (R1): <br />10 IN. H <br />Test End Time: <br />9:40 A.M. <br />Final Reading (Rf): <br />7 IN. H <br />Test Duration: <br />10 MIN. <br />Change in Reading (Rf-RI) <br />3 IN. H <br />Pass/Fail Threshold or Criteria: <br />Drop no lower than 8 <br />inch in one hour <br />Test Result: <br />I I Pass I x I Fail <br />I Pass Fail <br />[ Pass Fail <br />pass Fail <br />Was sensor removed for <br />testing? <br />[ ] Yes [ ] No [ ] N/A <br />[ ]Yes [ ] No [ ] N/A <br />[ ] Yes [ ] No [ ]N/A <br />[ ] Yes [ ] No [ ] N/A <br />Was sensor properly replaced <br />& verified functional after <br />testing? <br />[ ] Yes [ ] No [ ] N/A <br />[ ] Yes [ ] No [ ] N/A <br />[ ] Yes [ ]No [ ] N/A <br />[ ] Yes [ ] No [ ] N/A <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />XERXES TEST THRESHOLD STATES, IT CAN NOT DROP BELOW 8 INCHES Hg IN ONE HOUR <br />1 Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary containment, such as systems <br />that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment testing. (California Code of Regulations, Title 23, <br />Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.