Laserfiche WebLink
SWRCB. January 2002 <br />Page 4 of 7 <br />6. PIPING SUMP TESTING <br />Test Method Developed By: [ ] Sump Manufacturer [ X ] Industry Standard [ ] Professional Engineer <br />[ ] Other (Specify) <br />Test Method Used: [ ] Pressure [ ] Vacuum [ X ] Hydrostatic <br />[ ] Other (Specify) <br />Test Equipment Used: LAKE TEST Equipment Resolution: <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />1 If the entire depth of the sump is not tested, specify how much was tested. If the answer to ggy of the questions indicated with an asterisk (*) is "NO" or <br />"NA", the entire sump must be tested. (SWRCB LG -160) <br />Sump #1 <br />Sum # <br />Sump # <br />Sump # <br />Sump Diameter: <br />42 INCH <br />Sump Depth: <br />48 INCH <br />Sump Material: <br />FIBERGLASS <br />Height from Tank Top to Top <br />of Highest Piping Penetration: <br />24 INCH <br />Height from Tank Top to <br />Lowest Electrical Penetration: <br />14 INCH <br />Condition of sump prior to <br />testing: <br />DRY <br />Portion of Sump Tested <br />25 INCH <br />Does turbine shut down when <br />sump sensor detects liquid <br />both product & water)? <br />[ X ] Yes [ ] No [ ] NA <br />[ ] Yes [ ] No [ ] NA <br />[ ] YES [ ] NO [ ] NA <br />[ ] YES [ ] NO [ ] NA <br />Turbine shutdown response time: <br />Is system programmed for <br />fail-safe shutdown? <br />[X ] YES [ ] NO [ ] NA <br />[ ] YES[ ] NO [ ] NA <br />[ ] YES [ ] NO [ ] NA <br />[ ] YES [ ] NO [ ] NA <br />Was fail-safe verified to be <br />operational? <br />[ X] YES [ ] NO [ ] NA <br />[ ] YES [ ]NO[ ] NA <br />[ ] YES [ ] NO [ INA <br />[ ] YES [ ]NO[ ] NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />10 MIN. <br />Test Start Time: <br />10:30 AM, 12.05.02 <br />Initial Reading (RI): <br />25 INCH <br />Test End Time: <br />10:40 AM, 12.06.02 <br />Final Reading (Rf): <br />14 INCH <br />Test Duration: <br />24 HOURS <br />Change in Reading (Rf-R1) <br />11 INCH <br />Pass/Fail Threshold or <br />Criteria: <br />1/4 INCH IN 24 HRS. <br />Test Result: <br />I I Pass 1XI Fail <br />I I Pass I I Fail <br />Pass I Fail <br />I Pass I Pail <br />Was sensor removed for testing? <br />Yes No N/A <br />Yes No N/A <br />Yes No N/A <br />Yes No N/A <br />Was sensor properly replaced <br />and verified functional after <br />testing? <br />[ ] Yes[ ] No [ ] N/A <br />[ ] Yes [ ] No [ ] N/A <br />[ ] Yes [ ]No[ ]N/A <br />[ ]Yes[ ]No [ ] N/A <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />1 If the entire depth of the sump is not tested, specify how much was tested. If the answer to ggy of the questions indicated with an asterisk (*) is "NO" or <br />"NA", the entire sump must be tested. (SWRCB LG -160) <br />