COMPLIANCE INFO_2011-2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2011-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2021 4:50:00 PM
Creation date
6/23/2020 6:57:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2013
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2011-2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
416
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page of <br /> 7. UNDER-DISPENSER CONTAINMENT(UDQ TESTING <br /> Test Method Developed By: ❑UDC Manufacturer ®Industry Standard F1 Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum ®Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: Incon Incon TS-STS Tester Equipment Resolution: +/-0.002" <br /> mmmmmmmmmmmm <br /> UDC# 13 UDC# 14-15 UDC# 16 UDC# <br /> UDC Manufacturer: Unknown Unknown Unknown <br /> UDC Material: Fiberglass Fiber lass Fiberglass <br /> UDC Depth: 30" 30" 30" <br /> Height from UDC Bottom to Top 12" 12" 10" <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to N/A N/A N/A <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> Dry Dry Dry <br /> testing: <br /> Portion of UDC Tested 16" 16" 15" <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes ❑No k NA ❑Yes ❑No ®NA []Yes ❑No K NA ❑Yes ❑No ®NA <br /> product and water)?* <br /> Turbine shutdown response time <br /> Is system programmed for fail- ❑Yes []No k NA ❑Yes ❑No ®NA ❑Yes ❑No ®NA ❑Yes ❑No ®NA <br /> safe shutdown?* <br /> Was fail-safe verified to be ❑Yes ❑No k1NA ❑Yes ❑No ®NA ❑Yes ❑No ®NA ❑Yes ❑No ®NA <br /> o erational?* <br /> Wait time between applying <br /> pressure/vacuum/water and 15 minutes 15 minutes 15 minutes <br /> starting test <br /> Test Start Time: 2:45pm 3:01 pm 2:08pm 2:26pm 1:47pm 2:08pm <br /> Initial Reading (RI): 2.8551" 2.8546" 1.9652" 1.9665" 5.0565" 5.0552" <br /> Test End Time: 3:00pm 3:16pm 2:23 m 2:41 pm 2:02pm 2:23pm <br /> Final Reading RF): 2.8548" 2.8539" 1.9663" 1.9669" 5.0455" 5.0544" <br /> Test Duration: 15 Minutes Each 30 15 Minutes Each 30 15 Minutes Each 30 <br /> Change in Reading RF-RI : -0.0003 1 -0.0007 0.0011 0.0004 -0.011 -0.0008 <br /> Pass/Fail Threshold or Criteria: +/-0.002" +/-0.002" +/-0.002" +/-0.002 +/-0.002" +/-0.002" <br /> Test Result: 19 Pass ©.Fail K Pass 0 Fail 9 Pass 0 Fail 0 Pass0 Pail <br /> Was sensor removed for testing? ®Yes ❑No ❑NA ®Yes ❑No ❑NA 9 Yes ❑No ❑NA ❑Yes ❑No ®NA <br /> Was sensor properly replaced and k Yes ❑No ❑NA 9 Yes ❑No ❑NA 9 Yes ❑No ❑NA ❑Yes ❑No ®NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> *Unable to test; UDC#1-2,#3-4,#5-6,#7-8,#9-10,#11-12,#17&17s,#18&18s,#19& 19s,#20&20s,#21 &21 s, <br /> #22 &22s,#23&23s,#24&24s,#25 &25s,#26&26s,#27&27s,#28&28s,#29&29s and#30&30s. Due to missing boots. <br /> 2 2 013 <br /> ENVIRONMENTAL <br /> 'If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />