My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2011-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2021 4:50:00 PM
Creation date
6/23/2020 6:57:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2013
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2011-2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
416
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page of <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑Sump Manufacturer ®Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum 9 Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: Incon Incon TS-STS Tester Equipment Resolution: +/-0.002" <br /> Sump# 91 Tank#5 Sump# D-Tank#6 Sump# Sump# <br /> Sump Diameter: 42" 42" <br /> Sump Depth: 78" 77" <br /> Sump Material: Fiberglass Fiberglass <br /> Height from Tank Top to Top of 6" 8" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 40" 38" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Dry Dry <br /> Portion of Sump Tested' 44" 42" <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes []No ®NA ❑Yes ❑No ®NA ❑Yes ❑No ®NA ❑Yes ❑No ®NA <br /> product and water)?* <br /> Turbine shutdown response time <br /> Is system programmed for fail-safe ❑Yes ❑No R NA ❑Yes ❑No ®NA ❑Yes ❑No ®NA ❑Yes ❑No ®NA <br /> shutdown?` <br /> Was fail-safe verified to be ❑Yes []No [RNA ❑Yes ❑No ®NA ❑Yes ❑No ®NA ❑Yes ❑No ®NA <br /> o erational?" <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15 minutes 15 minutes <br /> test: <br /> Test Start Time: 12:10pm 12:26pm 11:33am 11:51 am <br /> Initial Reading(Ri): 2.0078" 3.3817" 2.9119" 2.9109" <br /> Test End Time: 12:25pm 12:41 pm 11:48am 12:07pm <br /> Final Reading(RF): 2.0070" 3.3814" 2.9125" 1 2.9116" <br /> Test Duration: 15 Minutes Each (30) 15 Minutes Each (30 <br /> Change in Reading(RF-Ri): -0.0008 -0.0003 0.00060.0007 <br /> Pass/Fail Threshold or Criteria: +/-0.002" +/-0.002"1+/-0.002" 1 +/-0.002 <br /> Test Result: I ® Pass ❑Fail ® Pass ❑Fail 0 Pass D Fail ❑ Pass D Fail <br /> Was sensor removed for testing? ®Yes ❑No ❑NA 9 Yes ❑No ❑NA ❑Yes ❑No ®NA ❑Yes ❑No ®NA <br /> Was sensor properly replaced and k Yes []No [INA 9 Yes ❑No ❑NA ❑Yes ❑No ®NA ❑Yes ❑No ®NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> * Unable to test: STP Diesel Tank#1,Tank#2 and Tank#3 due to missing boots. <br /> mr, III <br /> 1 <br /> ENVIBONMENTAL <br /> HEALTH EEIRVARTMENT <br /> ' If the entire depth of the sump is not tested,specify how much was tested. If the answer to as of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.