SAN JOAQ UIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility FIyg in J Travel Plaza Facility 1501 N. Jack Tone Road, Ripon Inspection May 14, 2014 <br /> Name: Address: pon Date: y <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=CA Health and Safety Code;CFR=Code of Federal Regulations <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) (M1) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (M7) <br /> Other Violations <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS 1,CLASS 11,or MINOR-Notice to Comply) <br /> This is a Routine and Monitoring System Certification. The following are Repeat Class II Violations: 201, <br /> 204,310,313 and Minor Violations - Notice to Comply : 203, 306 <br /> 203. About 2 cups of fuel release in the sump of the Bio-diesel Shed was not recorded. Any release <br /> from the primary containment that does not escape the secondary containment and was cleaned up <br /> within eight hours of being detected shall be recorded with the following information: <br /> 1. Operator's name and phone number <br /> 2. List of types, quantities, and concentrations of hazardous substances released <br /> 3. Description of actions taken to control and clean the release <br /> 4. Method and location of disposal of the released substances <br /> 5. Description of actions taken to repair and prevent future releases <br /> 6. Description of method used to reactivate interstitial monitoring after repair or replacement of <br /> primary containment <br /> Immediately record this release with the information required, and maintain it on site with the facility's <br /> monitoring records. Submit a copy of the recordable release statement to the EHD by June 14, 2014. <br /> 201 (Repeat). Maintenance/Service record responding to L6 alarm on 2/27/2014 was not found on site. <br /> These records shall be kept on site for at least 3 years. Immediately locate and maintain the on site <br /> and submit copies to the EHD by June 14, 2014. <br /> 204 (Repeat). The designated operator failed to document all the alarms from the attached alarm history <br /> on the designated operator monthly inspection report and failed to check that they were responded to <br /> appropriately. The missing alarms include: L6 alarm on 2/27/2014. During the monthly inspection, the <br /> designated operator shall review the alarm history for the previous month, check that each alarm was <br /> documented and responded to appropriately, and attach a copy of the alarm history with documentation <br /> taken in response to any alarms to the monthly report. Ensure that designated operators performing <br /> monthly inspections at this facility are including all of the required information on the reports. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspector Received By Title: <br /> >r <br /> i <br /> E 23-02 a 04/1 — e 3 UST INSPECTION REPORT <br />