My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2014-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/4/2021 4:36:01 PM
Creation date
6/23/2020 6:57:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2015
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2014-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
382
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ask <br /> San Joaquin County <br /> Environmental Health Department <br /> - 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> Facility Name: Facility Address: Date: <br /> FLYING J TRAVEL PLAZA#618" 1501 N JACK TONE RD RIPON May 14 2015 <br /> Item# Remarks <br /> 319 HSC 25291(e) Water in secondary containment not removed, analyzed, and properly disposed of(pre-Jul 2003). <br /> Liquid was observed in the following UST components: UDC-21 Sat(<0.5 cup), UDC-26 Sat(1/4 cup), Tank 1 STP <br /> (less than 0.5 gallons), and Tank 3 STP(less than 0.5 gallons). If water could enter into the secondary containment by <br /> precipitation or infiltration, it must be removed and disposed of properly. The service technician removed liquid from <br /> the aforementioned UST components. Ensure that all sumps and annular spaces are maintained free of liquid. This <br /> was corrected on site. <br /> This is a Class II violation. <br /> 320 HSC 25290.1(c3), 25290.1(c3) Secondary containment not constructed to prevent water intrusion. <br /> Water was found in the North Bio sump. Secondary containment shall be constructed to prevent any water intrusion <br /> into the system by precipitation, infiltration, or surface runoff. The service technician removed < 0.25 gallons of liquid <br /> from this sump and returned the sensor to its proper location. Immediately contact a properly licensed, trained, and <br /> certified contractor to address the water intrusion into the North Bio sump under permit and inspection of the EHD. <br /> This is a Class II violation. <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br /> The 87-octane line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of <br /> detecting a 3-gallon per hour leak at 10 psi. The leak detector was replaced and retested during the inspection. A <br /> "UST Retrofit Verification with Inspector Already Onsite" form has been completed and provided to the operator and <br /> contractor. This was corrected on site. <br /> This is a Class II violation. <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons. <br /> The Tank 4, Tank 5, and Tank 6 direct-bury spill containers failed when tested. All spill containers shall have a <br /> minimum capacity of five gallons and be capable of containing a spill or overfill until it is detected or cleaned up. The <br /> following spill container components were replaced and retested during the inspection: new drain in Tank 4, new"o" <br /> ring in Tank 5, and new drain in Tank 6. A"UST Retrofit Verification with Inspector Already Onsite"form has been <br /> completed and provided to the operator and contractor. This was corrected on site. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Routine underground storage tank (UST) inspection and monitoring system certification was conducted on May 14 <br /> and May 15, 2015; checklists of findings were left onsite each inspection day. The final inspection report was <br /> mailed to the facility on May 28, 2015. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork,30 days from receipt of this final inspection report. <br /> Received by �I . , .1 Inspector: Phone: Date: <br /> (initial): CX�t ELENA MANZO, REHS T(209) 953-7699 05/14/2015 <br /> Page 6 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.