8/26/2016 EGW.Guidelnfo-Tank Accessories for Flammable and Com ustible Liquids
<br /> INLINE CERTIFICADONS DIRECTORY °
<br /> EG .GuideInfo UG 2 6 2016
<br /> Tank Accessories for Flammable and Combustible Liquids 110
<br /> View Listings Page Bottom
<br /> [Containment Products for Flammable and Combustible Liquids] (Miscellaneous
<br /> Tanks, Storage Products and Tank Accessories) Tank Accessories for Flammable
<br /> and Combustible Liquids
<br /> See General Information for Miscellaneous Tanks, Storage Products and Tank Accessories
<br /> GENERAL
<br /> This category covers functional devices, materials and accessories intended for use in the construction of, or for attachment to, aboveground or
<br /> underground flammable and combustible liquid tanks, or their connecting piping as indicated under PRODUCT TYPES AND REQUIREMENTS
<br /> and in the individual certifications.
<br /> These products are intended for installation and use in accordance with ANSI/NFPA 30, "Flammable and Combustible Liquids Code," ANSI/NFPA
<br /> 30A, "Code for Motor Fuel Dispensing Facilities and Repair Garages," ANSI/NFPA 31, "Installation of Oil-Burning Equipment," ANSI/NFPA 1,
<br /> "Uniform Fire Code," or the "International Fire Code."
<br /> These products are intended to be factory assembled or field installed by qualified persons per the manufacturer instructions and, for continued
<br /> performance, require periodic inspection and maintenance or replacement.
<br /> PRODUCT TYPES AND REQUIREMENTS
<br /> The types of devices, materials and accessories as indicated in the individual certifications and the basic standards or requirements used to
<br /> investigate these products are as follows:
<br /> For Aboveground Combustible Liquid Tanks Only
<br /> Leg Bracket,Tank Support,Spill Dike,Lift Lug,Tank Fitting — Based on ANSI/UL 80, "Steel Tanks for Oil-Burner Fuel and Other
<br /> Combustible Liquids."
<br /> Fill Connector,Fill Cap,Vent Alarm,Vent Cap,Level Gauge — Based on ANSI/UL 180, "Liquid-Level Gauges for Oil Burner Fuels and
<br /> Other Combustible Liquids."
<br /> Oil-supply Pipe,Diesel Generator Pipe — Based on UL Subject 971A, "Outline of Investigation for Metallic Underground Fuel Pipe."
<br /> Nonmetallic Tub for Oil Tanks— Based on UL Subject 2258, "Outline of Investigation for Nonmetallic Tanks for Oil-Burner Fuels and Other
<br /> Combustible Liquids."
<br /> For Aboveground Flammable and Combustible Liquid Tanks
<br /> Tank Manway,Manway Cover,Tank Support,Gauge Hatch,Lift Lug,Access Device,Open-top Dike,Closed-top Dike,Pallet Tank—
<br /> Based on ANSI/UL 142, "Steel Aboveground Tanks for Flammable and Combustible Liquids."
<br /> For Underground Flammable and Combustible Liquid Tanks
<br /> Striker Plate,Tank Manway,Manway Cover,Tank Collar,Tank Riser,Lift Lug — Based on UL 58, "Steel Underground Tanks for
<br /> Flammable and Combustible Liquids," or ANSI/UL 1316, "Glass-Fiber-Reinforced Plastic Underground Storage Tanks for Petroleum Products,
<br /> Alcohols, and Alcohol-Gasoline Mixtures."
<br /> Dielectric Bushing or Reducer,Dielectric Coating,Anode Pack,Composite Tank Cap,Jacketed Tank Cap,Coated Tank Cap—
<br /> Investigated to ANSI/UL 1746, "External Corrosion Protection Systems for Steel Underground Storage Tanks," Part I, II, III or IV, as
<br /> appropriate.
<br /> Flow-restriction Device — Float-actuated valve intended for installation in a gravity-filled tank's vent opening, which automatically reduces
<br /> flow and closes when the tank is near capacity.
<br /> Vapor-control Products for Fuel Tanks
<br /> In accordance with UL 2583, "Outline of Investigation for Fuel Tank Accessories" (Part I for Vapor Control Products).
<br /> E-Vent — Pressure-actuated valve intended for connection to emergency-vent tank openings or connecting pipe intended to relieve excessive
<br /> internal pressures from overfilling or fire exposure.
<br /> N-Vent or P/V Vent — Dual pressure-and-vacuum-actuated valve intended for connection to normal tank openings or pipe to facilitate
<br /> pressure equalization during fill or withdraw operations, and barometric or temperature deviations.
<br /> Fill Adapter,Vapor Adapter or ATG Adapter— Pressure- or vacuum-actuated valves intended for connection to fill-and-vent hose or level-
<br /> gauge equipment to facilitate fuel delivery, vapor recovery or liquid-level monitoring.
<br /> http://database.ul.com/cgi-bi n/XYV/tem plate/LISEXT/1 FRAM E/shawpage.htmI?&name=EGW.Guideinfo&ccnshorttifle=Tank+Accessories+for+Flam m able+an... 1/3
<br />
|