My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JOE POMBO
>
2430
>
2300 - Underground Storage Tank Program
>
PR0506796
>
COMPLIANCE INFO_2006-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2021 2:56:37 PM
Creation date
6/23/2020 6:57:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2012
RECORD_ID
PR0506796
PE
2361
FACILITY_ID
FA0007634
FACILITY_NAME
ARCO AM PM #82602*
STREET_NUMBER
2430
STREET_NAME
JOE POMBO
STREET_TYPE
PKWY
City
TRACY
Zip
95376
APN
214-020-200-000
CURRENT_STATUS
01
SITE_LOCATION
2430 JOE POMBO PKWY
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506796_2430 JOE POMBO_2006-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
377
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page G of 8 <br /> 7. UNDER-DISPENSER CONTAINMENT C TESTING <br /> Test Method Developed By: ❑UDC Manufacturer ❑Industry Standard ofessional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum kAydrostatic <br /> ❑-Other(Sped) <br /> Test Equipment Used: Cs ld 0 e A I-e-e..L Equipment Resolution: <br /> UDC# 4 i/v UDC# I ttZ C# C# <br /> UDC Manufacturer: W eS --e_✓v® L4<, r^ <br /> UDC Material: t 6" N S s P t tuvt 1&Se <br /> UDC Depth: 3 31/i3q-" <br /> Height from UDC Bottom to Top <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to ,�1 r 19 rI <br /> testing: ►r/ <br /> Portion of UDC Tested o, a o vj LI°° <br /> Does turbine shut down when <br /> UDC sensor detects liquid(bothes ❑No 11NA Yes ❑No ❑NA ElYes N ❑NA ❑Yes No ❑NA <br /> roduct and water)?* r t \ - <br /> Turbine shutdown response time y 4-t,-c , t <br /> Is system programmed for fail- If-Yes ❑No ❑NA Aes ❑No ❑NA ❑Yeso ❑NA ❑Yes ❑ ❑NA <br /> safe shutdown? <br /> * 4 <br /> Was fail-safe verified to be <br /> operational?* ❑yes o ❑NA 1:1 Yes o ❑NA 0 Yes o ❑NA ❑Yes ❑ o 11NA <br /> Wait time between a lying <br /> pressure/vacu ater d <br /> starting test Lo 1--t:ba V( (® r-t <br /> Test Start Time: ; <br /> Initial Reading j : ( °'v b Vic, `r � <br /> Test End Time: i l: t Z: vv <br /> Final Reading a 1. 4-cwctp Ens4-c,,xc& <br /> Test Duration: - 3o yya�\ 3 <br /> Chane in Reading(RF-RI): yvo !v0 <br /> Pass/Fail Threshold or Criteria: v v o A,n . - V a 6,V'1,3 6 14;, <br /> Test Result: ass D Fail Pass O Fail 10 Pass ❑F it ❑ Pass ❑Fail <br /> Was sensor removed for testing? es ❑No ❑NA es ❑No ❑NA ❑Yes ❑No ❑ A ❑ ❑No ❑NA <br /> Was sensor properly replaced andyes ❑No ❑NA Yes ❑No ❑NA 0 Yes ❑No ❑LA es ❑No ❑NA <br /> verified functional after testin ? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> 'If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any of tha questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />