Laserfiche WebLink
TANKNOLOGY <br /> Stage II Vapor Recovery Test Results Form <br /> Air/Liquid Ratio Test For Vacuum Assist Systems <br /> Site Information: 7-ELEVEN#32262 2360 GRANTLINE I-205 OFF RAMP TRACY CA.95376 <br /> Work Order#: 2222223 Date: 05/15/2002 Technician: MICHAEL T LEVESQUE <br /> Product Flow Rate Calculation Air Volume Metered(ft^3) Ambient Conditions Corrected Final <br /> Gallons(g) Time(s) Flowrate Initial Final Volume Pressure Temp. Air Volum Calculated AAL Ratio Results <br /> Nozzle# Product Dispensed Seconds G.P.M. Reading Reading Metered Inches Hg Degrees F (ft^3) A/L Average Pass/Fail <br /> 7.502 54.90 8.2 2921.22 2922.34 1.120 1.12 <br /> 1 opw 27r REG 1.12 Pass <br /> 7.510 49.90 9.0 2922.34 2923.48 1.140 1.14 <br /> 1 opw 27r PREMIUM 1.14 Pass <br /> 7.499 48.91 9.2 2923.48 2924.62 1.140 1.14 <br /> 1 opw 27r PLUS 1.14 Pass <br /> 7.504 55.28 8.1 2924.62 2925.66 1.040 1.04 <br /> 2 opw 27r REG 1.04 Pass <br /> 7.516 50.25 9.0 2925.66 2926.72 1.060 1.06 <br /> 2 opw 27r PREMIUM 1.06 Pass <br /> Type of System Tested: Gilbarco Vapory <br />