My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
755
>
2300 - Underground Storage Tank Program
>
PR0508090
>
COMPLIANCE INFO_1998-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 8:31:25 AM
Creation date
6/23/2020 6:58:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2006
RECORD_ID
PR0508090
PE
2361
FACILITY_ID
FA0007938
FACILITY_NAME
CHEVRON #208117**
STREET_NUMBER
755
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
24202029
CURRENT_STATUS
01
SITE_LOCATION
755 S TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508090_755 S TRACY_1998-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
427
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7. U R -DISPENSER CONTAINMENT ( TESTING <br />Test Method Developed By: UDC Manufacturer ❑ Industry Standard ® Professional Engineer ❑ <br />Other (Specify) <br />Test Method Used: Pressure ❑ Vacuum ❑ Hydrostatic <br />Other (Specify) <br />Test Equipment Used: Wayne Perry Inc. See Attached Testing Results Equipment Resolution: .00007 <br />Under -Dispenser Containment Number Below <br />Comments — (include information on repairs made prior to testing and recommended follow-up for failed tests) <br />Chevron -208117 <br />755 S. Tracy Blvd. <br />Tracy, CA 95376 <br />N05204-SB989 Testing <br />UDC Manufacturer: <br />UDC Material: . ,G. � <br />°� t,-Ga•-i�c.- : - '"e,�-s <br />fit-'��L =-%�-q <br />UDC Depth: 27 „ <br />-27 <br />2-1 <br />2 %" <br />77" <br />Z 7" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: 7 " <br />" <br />% <br />{c <br />7 <br />7 <br />7 <br />7 <br />Height from UDC Bottom to jr " <br />Lowest Electrical Penetration: <br />" <br />" <br />1z <br />" <br />" <br />/Z <br />" <br />Condition of UDC prior to <br />testing: �, <br />°ter <br />�°.. e-+? <br />�� <br />_ <br />Portion of UDC Tested' 2" Above Highest <br />Penetration <br />2" Above Highest <br />Penetration <br />2" Above Highest <br />Penetration <br />2" Above Highest <br />Penetration <br />Does turbine shut down when ❑ Yes ❑ No NA® <br />UDC sensor detects liquid. <br />❑ Yes ❑ No NA® <br />❑ Yes ❑ No NA® <br />❑ Yes ❑ No NA® <br />Turbine shutdown response time ❑ Yes ❑ No NA® <br />❑ Yes ❑ No NAM <br />❑ Yes ❑ No NA® <br />❑ Yes ❑ No NA® <br />Is system programmed for fail- ❑ Yes ❑ No NA® <br />safe shutdown?* <br />❑ Yes ❑ No NA® <br />❑ Yes ❑ No NA® <br />❑ Yes ❑ No NAM <br />Was fail-safe verified to be ❑ Yes ❑ No NAM <br />opera ional?* <br />❑ Yes ❑ No NA® <br />❑ Yes ❑ No NA® <br />❑ Yes ❑ No NAN <br />Wait time between applying <br />pressure/vacuum/water and 15 Minutes <br />starting test <br />15 Minutes <br />15 Minutes <br />15 Minutes <br />Test Start Time: 2,a '/ f7 _°fel <br />: -7 y / 3 y <br />2--i3 7 0 Y7 <br />Initial Reading (Rj): /7, i7e z <br />! <br />Test End Time: '® cc /.1 C <br />/. y 1 <br />2: z V 7 m 5- - <br />Final Reading (RF): o' 3 Z /? i7t' <br />/. ` S Z• `39 <br />tZ. 70 /Y. 1S vc' <br />Test Duration: 15 Min 15 Min <br />15 Min 15 Min <br />15 Min 15 Min <br />15 Min 15 Min <br />Change in Reading (RrRO: Cv 0 Ir I pea C <br />, 6104; - _'Ci 000 ` <br />.-Cepo . ve'v <br />Pass/Fail Threshold or Criteria: -0.0020 -0.0020 <br />-0.0020 -0.0020 <br />-0.0020 -0.0020 <br />-0.0020 -0.0020 <br />Tett� <br />a&sss <br />Was sensor removed for testing? 0 Yes ❑ No NAE] <br />® Yes ❑ No NA❑ <br />® Yes ❑ No NAE] <br />❑ Yes ❑ No NA❑ <br />Was sensor properly replaced and M Yes ❑ No NAE] <br />verified functional after testing? <br />® Yes ❑ No NAE] <br />l%7 Yes ❑ No NAE] <br />❑ Yes ❑ No NAE] <br />Comments — (include information on repairs made prior to testing and recommended follow-up for failed tests) <br />Chevron -208117 <br />755 S. Tracy Blvd. <br />Tracy, CA 95376 <br />N05204-SB989 Testing <br />