My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
755
>
2300 - Underground Storage Tank Program
>
PR0508090
>
COMPLIANCE INFO_1998-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 8:31:25 AM
Creation date
6/23/2020 6:58:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2006
RECORD_ID
PR0508090
PE
2361
FACILITY_ID
FA0007938
FACILITY_NAME
CHEVRON #208117**
STREET_NUMBER
755
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
24202029
CURRENT_STATUS
01
SITE_LOCATION
755 S TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508090_755 S TRACY_1998-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
427
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Chevron -208117 <br />755 S. Tracy Blvd. <br />Tracy, CA 95376 <br />N05204-SB989 Testing <br />8. &L RISER CONTAINMENT SUMP T ING Page 6 of <br />Facilit is Not Eguipped With Fill Riser Containment Sums ❑ <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: <br />❑ Sump Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: <br />❑ Pressure <br />❑ Other (Specify) <br />❑ Vacuum <br />® Hydrostatic <br />Test Equipment Used: Wayne Perry Inc. See Attached Results <br />Equipment Resolution: .0007" <br />Sump # T 7 <br />Sump # y/ <br />Sump # Sump # <br />Sump Diameter:' <br />Sump Depth: <br />7 f- " <br />7 5' <br />" <br />Sump Material:, <br />-- <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />6 <br />„ <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />36 <br />„ <br />Condition of sump prior to testing: <br />Portion of Sump Tested' <br />2" ABOVE HIGHEST <br />PENETRATION <br />2" ABOVE HIGHEST <br />PENETRATION <br />2" ABOVE HIGHEST 2" ABOVE HIGHEST <br />PENETRATION PENETRATION <br />Wait time between applying water <br />and starting test: <br />15 Minutes <br />15 Minutes <br />15 Minutes 15 Minutes <br />Test Start Time: <br />0 <br />9 <br />Initia <br />/C,_ <br />Test End Time: <br />a 3'� <br />` <br />Final Reading (RF): <br />C- <br />Test Duration: <br />15 Min 15 Min <br />15 Min 15 Min <br />15 Min 15 Min 15 Min 15 Min <br />Change in Reading (RF-RO: <br />, 100 3 3 <br />1-'ov z I <br />Pass/Fail Threshold or Criteria: <br />-0. 1-0.0020 <br />-0.0020 1 -0.0020 <br />-0.0020 1 -0.0020 -0.0020 1 -0.0020 <br />mx <br />Is there a sensor in the sump? <br />tffl Yes ❑ No ❑ NA <br />IA Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />Does sensor alarm when either <br />product or water is detected? <br />Yes ❑ No ❑ NA <br />(4 Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />Was sensor removed for Testing? <br />5d Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />®Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Chevron -208117 <br />755 S. Tracy Blvd. <br />Tracy, CA 95376 <br />N05204-SB989 Testing <br />
The URL can be used to link to this page
Your browser does not support the video tag.