Page 9 <br />of <br />A PTPiN(: RITMP TRCTTNG <br />Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Spec6) <br />Test Equipment Used: Wayne Perry Inc. <br />Equipment Resolution: .0007" <br />MENEM= <br />Sump # .7 <br />Sump # / <br />Sump # <br />Sump # <br />Sump Diameter: <br />Sump Depth: <br />Sump Material: <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />Condition of sump prior to testing: <br />Sump <br />Portion of Sum Tested' <br />2" ABOVE HIGHEST <br />PIPING PENETRATION <br />2" ABOVE HIGHEST <br />PIPING PENETRATION <br />2" ABOVE HIGHEST <br />PIPING PENETRATION <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?* <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ®NA <br />❑ Yes ❑ No ®NA <br />❑ Yes ❑ No ❑ NA <br />Turbine shutdown response time <br />NA <br />NA <br />NA <br />Is system programmed for fail-safe <br />shutdown?` <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ❑ NA <br />Was fail-safe verified to be <br />operational?* <br />❑ Yes []No ® NA <br />❑ Yes ❑No ® NA <br />❑ Yes []No R NA <br />❑ Yes ❑ No ❑ NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />15 Minutes <br />15 Minutes <br />15 Minutes <br />15 Minutes <br />Test Start Time: <br />/.; v s- <br />59 .` ;13 <br />Initial Reading (Ro: <br />i S <br />' 5-2 <br />Test End Time: <br />®, Z j <br />Y: -/?- <br />Final <br />Final Reading (RF): <br />f'0, <br />Test Duration: <br />15 Min 15 Min <br />15 Min 15 Min <br />15 Min 15 Min <br />15 Min 15 Min <br />Change in Reading (RF -R): <br />o ;Z_5 <br />ZZ40/0 <br />Pass/Fail Threshold or Criteria: <br />-0.0020 -0.0020 <br />-0.0020 1 -0.0020 <br />-0.0020 -0.0020 <br />-0.0020 -0.0020 <br />Test Result: - <br />(KI -Pass ❑ Fait <br />®--Pass ' ❑ Fail <br />❑ Pass ❑ Fail <br />❑Pass ❑Fail <br />Was sensor removed for testing?19 <br />Yes ❑ No [INA <br />Yes El No ❑ NA <br />10 Yes El No ❑ NA <br />® Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />M Yes ❑ No ❑ NA <br />Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Mevron # 208117 <br />755 S Tracy Blvd <br />Cracy, Ca <br />18128 SB989 <br />