Chevron Monitoring Cer i ication Checklist <br />Store Number: 208117 <br />Address: 755 S. TRACY BLVD TRACY, CA 95376 <br />Date: 2/2/2018 <br />Technician: Tim Elebeck <br />Company: TANKNOLOGY INC. <br />Step <br />Instruction <br />T1 <br />T2 <br />Product <br />PREMIUM <br />REGULAR <br />Tank Type <br />Fiberglass <br />Fiberglass <br />(DW FRP, DW Steel, SW FRP) <br />1 <br />Annular Riser Height (measured) <br />78.50 in. <br />77.00 in. <br />2 <br />Tank Diameter: (from tank chart, <br />117.75 in. <br />117.75 in. <br />for example: 118.375",117.75",111 ",92",etc.) <br />3 <br />For FRP tanks, 1/2 circumference of the tank <br />184.87 in. <br />184.87 in. <br />(0.5 X3.14 X tank diam.) OR (q.57 x step 2) <br />Required annular sensor length: <br />4 <br />FRP = Riser + 112 Circumference = step 1 + step 3 <br />263.37 in. <br />261.87 in. <br />Steel = Riser + diameter = step 1 + step 1 <br />Mark & label the required sensor length on <br />S <br />sensor cord. Label should be under the cap & <br />Yes <br />Yes <br />serve to prevent the cord being pulled too short. <br />Is tank annular sensor in the correct position? <br />Yes <br />Yes <br />6 <br />FRP Tanks: with the marked required length <br />lining up with the top of the annular riser? <br />Yes <br />Yes <br />Steel Tanks: sensor touching bottom with slack <br />above the marked required sensor length? <br />Are the DW pipe boots pulled back in tank sumps? <br />8 <br />(YIN or N/A, note if can't be verified because <br />Yes <br />Yes <br />clamshell pointing down) <br />Are tank sump sensors back in their holders and <br />9 <br />in the correct position? <br />Yes <br />Yes <br />(YIN or N/A document with photo) <br />Approximate gallons of product dispensed for <br />7 <br />purging, etc. and returned to tank <br />Has the Veeder Root Battery been replaced & dated prior to failsafe? <br />(If battery backup failed, label and leave failed battery on top of console, note in comments and advise your OM) <br />Replaced Today <br />Has Veeder Root Programming before & after testing been printed & verified? Yes <br />(especially tank manifolding setup - see Note 2) <br />Has Veeder Root Programming before & after been attached to the Work Order? Yes <br />Have all sensor model numbers been verified against the Veeder Root cord label? Yes <br />Make a note if sensor label missing or illegible, & approx. cord length for -208/-209 with missing labels <br />Additional Comments: <br />Note 1: Certain Veeder Root Software versions will automatically revert to the default tank manifold settings anytime the programming is changed, such as when sensors are <br />temporarily X'ed out, etc. <br />