Laserfiche WebLink
Alcohols,t•Aviation, <br />Gasoline, Diesel <br />Pump <br />Integrated• Any Pipeline System <br />• CheckValve/ Pressure Relief <br />Certification• Combined Rigid and Flexible Pipe <br />! to # gallons <br />• Rigid <br />!` r! only <br />Certification !': o 406 gallons <br />• Smallest profile <br />/ month <br />Now Available! FactoryCertifications! <br />Installation !AnnualTesting" <br />Field Adjustable Leak Threshold <br />New Certification Applicable With Any Pipe Configuration: Largest volume / longest line <br />and now Certified for combination of rigid and flexible pipe app to 502 gallons. The 99 LD -3000 is certified <br />for the following pipe: 1171 feet of 3" 1.D. rigid pipe, up to 406 gallons; 260 feet of 3" 1.D. flexible pipe, up to 96 gallons; <br />1431 feet combination of rigid and flexible pipe, up to 502 gallons. <br />Longest Guarantee: The 99 LD -3000 series shares the longest guarantee available in the industry with the Vmi <br />99 LD -2000 and 99 LD 2200 series leak detectors. For 24 months after installation, the 99 LD -3000 is guaranteed to <br />see a 3 GPH @ 10 PSI leak. <br />Now With Quick Purge Line Feature: At installation, the 99 LD -3000 is open, ready to purge the line sys- <br />tem. After line is purged, one screw is removed to enable leak detection function. <br />Electronic Line Leak Detection Upgrade! The 99 LD -3000 maybe upgraded in the field to eliminate thermal <br />induced slow -flow, provide submersible shut -down, and alarm notification to site monitoring equipment. Request information <br />on the ISM -4080, an easy upgrade for existing or new installations. The ISM -4080 also stages turbines and controls <br />solenoid valves for loading racks and marine applications. If there is no need for staged turbines, solenoid valve control, <br />alarm notification or submersible shut -down, request information on the ARM -4073 to eliminate false alarms only. <br />Field Adjustable LeakThreshold: All Vmi mechanical line leak detectors have been factory assembled and <br />tested to meet the EPA leak detection threshold established during certification testing. Abnormal field conditions such <br />as high line resiliency (high bleed -back), pump pressures over 40 PSI and high head pressures affect line leak detection <br />sensitivity. Additionally, wear affects performance of leak detection over time. To meet these issues, Vmi established <br />through certification testing, the ability of field technicians to adjust Vmi mlld's to compensate for field variables and <br />normal wear. Please read Technical Bulletin 032805 for specific instructions on this feature. M f M $;_ a <br />See Technical Specifications on back under Fuels <br />" Contact factory for details YR U.S. Patent No. 4,966,190 • Designed and Manufactured in U.S.A. MMMM ,s` <br />