My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15237
>
2300 - Underground Storage Tank Program
>
PR0517272
>
COMPLIANCE INFO_2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 10:41:44 AM
Creation date
6/23/2020 6:59:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011
RECORD_ID
PR0517272
PE
2361
FACILITY_ID
FA0012979
FACILITY_NAME
FLYING J TRAVEL PLAZA #617
STREET_NUMBER
15237
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
02519014
CURRENT_STATUS
01
SITE_LOCATION
15237 N Thornton Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0517272_15237 N THORNTON_2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
321
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
This pumping system requires the following elements: <br />1. Discharge Manifold Assembly - Installed below grade (NEC/Class 1, Group D, Division I area) <br />2. Motor -Pump Unit Assembly -Installed below grade (NEC/Class I, Group D, Division I area) <br />3. Control Box/Magnetic Starter <br />An ".all inclusive" name plate will be found attached to the Extracta Head and can be inspected by removing <br />the manhole cover directly over the pump. <br />An additional name plate will be found on the control box. It is important to give the model number and serial <br />number of this pump when corresponding With the factory for any reason. <br />Read This Important Safety Information Before Beginning Work. <br />1. Units should be installed with manholes, or with discharge manifold casting above grade, to allow for ease in <br />servicing. <br />Red Jacket line leak detection systems do not function if the submersible pump runs continuous- <br />ly. Running a pump continuously will cause line leak detection systems to not function which re- <br />sults in a hazard that can cause damage to property, environment, resulting in serious Injury or <br />death. <br />2. Never wire a submersible pump to run continuously at less than minimum flow rate. The units are designed to <br />operate continuously at or above minimum flow rate, or with an intermittent duty cycle, not to exceed 20 on/off <br />cycles per hour.. Should it be necessary to operate a unit continuously or when the demand is at a rate less <br />than required per the information below, a bypass pipe should be installed in the piping to allow for continual <br />product recirculation back into the storage tank. Regulation of the bypass flaw back to the tank can be <br />accomplished by correct sizing of the bypass line or use of a gate valve. The recommended minimum bypass <br />per unit is shown in Table A. <br />Table A. <br />60 Hz, 208-240, 575 Volt <br />Two Stage Units <br />50 Hz 380-415 Volt <br />Three Stage Units <br />P200J1-2MB = 15 GPM <br />P300J17-3HB = 20GPM <br />P200J4-2MB = 15 GPM <br />P500J 17-3K = 25 GPM <br />P300J4-2HB = 20 GPM <br />P300J16-3H8 = 20GPM <br />P500J4-2K=25 GPM <br />P500J16-3K=25 GPM <br />t <br />P200J6-2K=25 GPM <br />3. Red Jacket submersibles are not designed1to handle abrasives or foreign particles in the product being <br />pumped. <br />4. Product temperature must never exceed 105°F (41 °C) as the submersible motors are equipped with thermal <br />overload protection; Product temperature higher than 105T (41 °C) may result in tripping of the thermal <br />overload protector. <br />5. Pumping water will overload the motor and damage the motor bearings. <br />e <br />
The URL can be used to link to this page
Your browser does not support the video tag.