COMPLIANCE INFO_2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15237
>
2300 - Underground Storage Tank Program
>
PR0517272
>
COMPLIANCE INFO_2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 10:41:44 AM
Creation date
6/23/2020 6:59:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011
RECORD_ID
PR0517272
PE
2361
FACILITY_ID
FA0012979
FACILITY_NAME
FLYING J TRAVEL PLAZA #617
STREET_NUMBER
15237
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
02519014
CURRENT_STATUS
01
SITE_LOCATION
15237 N Thornton Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0517272_15237 N THORNTON_2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
321
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L <br />F. SYSTEM PIPING CONTINUED: <br />Check <br />Code <br />Box <br />Section <br />Overspill containmnt having minimum capacity ol.5 11 provided provided at each tank fill location. <br />HSC <br />Piping compatible with material intended to be stored. <br />25290.1 c 1 <br />Approved overfill prevention device provided at each tank fill location. <br />25290.2 c 1 <br />Choose One of the following methods: <br />/ <br />23 CCR <br />Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br />1/ <br />2631(b) <br />Design and construction of piping approved by independent testing organization (e.g. UL). <br />Piping, including vent lines, sloped toward tank(s) with minimum 1/4 inch slope per 1 foot of run. <br />23 CCR <br />restriction occurs when the tank is filled to no more than 95 percent capacity; and activate an <br />2 290.1 k <br />Vapor recovery, fill riser, and vent line piping are secondarily contained. <br />25290.2�c3&0) <br />Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br />G. OVERSPILL/ OVERFILL PREVENTION: <br />Check <br />Box <br />Code <br />Section <br />Box <br />23 CCR <br />2635(b) <br />Overspill containmnt having minimum capacity ol.5 11 provided provided at each tank fill location. <br />Manufacturer Model <br />1-23 <br />Approved overfill prevention device provided at each tank fill location. <br />CCR <br />Choose One of the following methods: <br />/ <br />2636(b) <br />Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br />1/ <br />triggering an audible visual alarm <br />Restrict delivery of flow to the tank at least 30 minutes before the tank overfills, provided the <br />23 CCR <br />restriction occurs when the tank is filled to no more than 95 percent capacity; and activate an <br />2635(b)(2) <br />audible alarm at least five minutes before the tank overfills <br />Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br />capacity. <br />Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the <br />tank are exposed to product due to overfilling. <br />Manufacturer V i,elQ QQF-e0l Model V k --M0001 <br />H. CORROSION PROTECTION: <br />Check <br />Code <br />Box <br />Section <br />Fiberglass reinforced plastic (FRPL <br />1-23 <br />Piping corrosion protection: Steel with cathodic protection or impressed current <br />CCR <br />Steel isolated from contact with backfill <br />2636(b) <br />FRP or equivalent non-metallic exterior coatinns or coverings <br />Tank corrosion protection: Sacrificial Anode <br />2635( j(2) <br />Steel tank with field installed cathodic protection or impressed <br />current <br />Tie -downs, when used, constructed of non -corrosive material or coated steel. <br />Revised 07/22/10 <br />