My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15237
>
2300 - Underground Storage Tank Program
>
PR0517272
>
COMPLIANCE INFO_2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 10:41:44 AM
Creation date
6/23/2020 6:59:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011
RECORD_ID
PR0517272
PE
2361
FACILITY_ID
FA0012979
FACILITY_NAME
FLYING J TRAVEL PLAZA #617
STREET_NUMBER
15237
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
02519014
CURRENT_STATUS
01
SITE_LOCATION
15237 N Thornton Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0517272_15237 N THORNTON_2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
321
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />• <br />I. MONITORING: All monitoring equipment must be listed in the State Waster Resources Control Board <br />Division of Clean Water Program Local Guidance Letter 113. <br />Check <br />Box <br />Code <br />Section <br />MODEL <br />COMPOSITION <br />SUMPXe�Xe <br />All secondary containment units (e.g. tank annular spaces, secondary piping, sumps, <br />23 CCR <br />under-dispenser containment, etc.) monitored for leaks using approved electronic leak <br />2636 (fl <br />detections stems. <br />PENETRATIONS <br />(� <br />V �� �lV1Q <br />All sensors must be located at the lowest possible point so that they may detect a leak <br />at the earliest opportunity. <br />Electronic monitoring sensors located at the following points: <br />° At the bottom of the interstitial space of each secondarily -contained tank, <br />positioned as near as possible to the bottom of the tank. <br />Manufacturer Vetki, (44- Model VK_2 q3 <br />° In each collection sump, positioned as near as possible to the bottom of the <br />collection sump. Additionally, in any sump acting as secondary containment for <br />unused tank openings which connect to the primary space. <br />23 CCR <br />Manufacturer U eeoQt,, (-v4 Model V 4-79q380 -3 - 3 <br />2632 <br />2630 (d) <br />° In dispenser pans which do not drain into secondary containment piping. <br />(Note: A mechanical switch which triggers a shear valve may be substituted but <br />this system will not qualify for the annual line tightness test exemption under 23 <br />CCR 2636(8)). <br />pp <br />Veek �0 + VK--'N3K0-_*-3 <br />Manufacturer Model <br />Along secondarily -contained pipe runs which do not meet the 1/4 inch -per -foot <br />slope requirement, positioned in the depressed or low-lying areas. <br />Manufacturer Model <br />23 CCR <br />Automatic line leak detectors installed to monitor underground pressurized piping. <br />2636(f <br />HSC <br />Manufacturer Model <br />25290.1 h <br />25290.2 <br />Alarm panel provides both audible and visual alarms. It is located in a protected area <br />and within sight and hearing distance of on-site personnel and hard -wired to a <br />23 CCR <br />2632(c)(2)(B) <br />dedicated circuit. <br />11 <br />Manufacturer VJ1 �" Model --J—LS 3S 0 <br />J. OTHER COMPONENT INFORMATION: <br />COMPONENT <br />MANUFACTURER <br />MODEL <br />COMPOSITION <br />SUMPXe�Xe <br />5 <br />I �e-r- 1(4 <br />UNDER -DISPENSER <br />CONTAINMENT <br />PENETRATIONS <br />(� <br />V �� �lV1Q <br />V�rl oqs <br />Revised 07/22/10 <br />