Laserfiche WebLink
0 <br /> SWRCB,January 2002 Page of <br /> 7. UNDER-DISPENSER CONTAINMENT(KPfj TESTING <br /> Test Method Developed By: i__'UDC Manufacturer LK Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum ®Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: Incon Incon TS-STS Tester Equipment Resolution: +/-0.002" <br /> UDC# 1-2 UDC# 3-4 UDC# 5-6 UDC# 7-8 <br /> UDC Manufacturer: Unknown Unknown Unknown Unknown <br /> UDC Material: Fiber lass Fiberglass Fiberglass Fiberglass <br /> UDC Depth: 31" 31" 31" 31" <br /> Height from UDC Bottom to Top 14" 14" 13" 13" <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 4" 4" 2" 3" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Good Good Good Good <br /> testing: <br /> Portion of UDC Tested 17" 17" 16" 17" <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> product and water)?* <br /> Turbine shutdown response time <br /> Is system programmed for fail- Yes []No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> safe shutdown?* <br /> Was fail-safe verified to be ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes '❑No '=i NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and 15 minutes 15 minutes 15 minutes 15 minutes <br /> starting test <br /> Test Start Time: 3:37pm 3:56pm 3:03pm 3:19pm 1:35pm 1:54pm 1:35pm 1 1:54pm <br /> Initial Reading (RI): 3.8379" 3.8379" 3.9395" 3.9394" 4.7342" 4.7033" 2.6085" 2.6078" <br /> Test End Time: 3:52pm 4:12pm 3:18pm 3:34pm 1:50pm 2:09pm 150 m 2:09 m <br /> Final Reading(RF): 3.8379" 3.8380" 3.9393" 3.9391" 4.7344" 4.7053" 2.6090" 2.6082" <br /> Test Duration: 15 Minutes Each 30 15 Minutes Each 30 15 Minutes Each 30 15 Minutes Each 30 <br /> Change in Reading (RF-RI): 10.0000 1 0.0001 -0.0002 -0.0003 -0.0002 0.002 0.0005 0.0004 <br /> Pass/Fail Threshold or Criteria: +/-0.002" +/-0.002" +/-0.002" +/-0.002 +/-0.002" +/-0.002" +/-0.002" +/-0.002" <br /> Test Result:`' 91 Pass 0 Fail ® Pass 11 Fail 91 Pass O Fail 91 Pass 1]Fail <br /> Was sensor removed for testing? X Yes ❑No ❑NA ®Yes ❑No ❑NA X Yes ❑No ❑NA ®Yes ❑No ❑NA <br /> Was sensor properly replaced and k Yes ❑No ❑NA C Yes ❑No ❑NA ®Yes ❑No ❑NA 9 Yes ❑No ❑NA <br /> verified functional after testin ? <br /> Comments-(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />