COMPLIANCE INFO_JAN 2011-JUN 2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15237
>
2300 - Underground Storage Tank Program
>
PR0517272
>
COMPLIANCE INFO_JAN 2011-JUN 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 10:41:46 AM
Creation date
6/23/2020 6:59:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
JAN 2011-JUN 2011
RECORD_ID
PR0517272
PE
2361
FACILITY_ID
FA0012979
FACILITY_NAME
FLYING J TRAVEL PLAZA #617
STREET_NUMBER
15237
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
02519014
CURRENT_STATUS
01
SITE_LOCATION
15237 N Thornton Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0517272_15237 N THORNTON_JAN 2011-JUN 2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
316
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Vaporless Mfg. LD 3000/30005 <br /> 1.0 Introduction <br /> The Vaporless LD 3000 mechanical leak detector is designed for hourly monitoring of <br /> large-capacity, high through-put pumps and lines. The LD 3000S is identical to the LD <br /> 3000 with the exception of a electrical switch added to provided external control signals. <br /> The LD 3000 and LD 3000S were previously evaluated and reported on in 1993 using <br /> 350' of Ameron fiberglass pipe containing 158 gallons of product. The evaluation was <br /> conducted using the Federal EPA's "Standard Test Procedures for Evaluating Leak <br /> Detection Methods: Pipeline Leak Detection Systems," EPA/530/UST-90/01 0, <br /> September 1990. The evaluation results were published in the report "Evaluation of the <br /> Vaporless LD 3000 and LD 3000S Line Leak Detector for Hourly Monitoring", August <br /> 20, 1993. This report and the EPA Protocol should be referred to for full details of the <br /> 1993 evaluation. <br /> Since that evaluation was performed, larger volume rigid and flexible pipelines are <br /> available for use in new construction and site upgrades. These larger pipelines can <br /> exceed the maximum 316 gallons pipeline volume allowed for the LD 3000/3000S in the <br /> 1993 evaluation. <br /> This new evaluation was performed on larger diameter rigid and flexible lines with <br /> increased volumes. Three types of pipe line configurations were used: rigid pipe only, <br /> flexible pipe only and rigid/flexible pipe combined. The testing procedures satisfy all of <br /> the requirements for a full EPA evaluation with the exception that only 6 tests were run <br /> per pipeline configuration rather than the minimum 50 tests called for by the Standard <br /> Test Procedures. <br /> Page 1 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.