COMPLIANCE INFO_JAN 2011-JUN 2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15237
>
2300 - Underground Storage Tank Program
>
PR0517272
>
COMPLIANCE INFO_JAN 2011-JUN 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 10:41:46 AM
Creation date
6/23/2020 6:59:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
JAN 2011-JUN 2011
RECORD_ID
PR0517272
PE
2361
FACILITY_ID
FA0012979
FACILITY_NAME
FLYING J TRAVEL PLAZA #617
STREET_NUMBER
15237
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
02519014
CURRENT_STATUS
01
SITE_LOCATION
15237 N Thornton Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0517272_15237 N THORNTON_JAN 2011-JUN 2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
316
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Vaporless Mfg. LD 3000/3000S <br /> 2.0 Description of the Testing Location & Equipment <br /> The Vaporless Manufacturing LD 3000/LD 3000S was evaluated at the Fuels <br /> Management Research Center located in Grain Valley, Missouri, which is operated by <br /> Ken Wilcox Associates, Inc. Three different pipeline configurations were tested during <br /> the evaluation. <br /> The evaluation system consisted of: <br /> • A 600 gallon steel product tank containing gasoline that was kept at <br /> predetermined temperature by an external heat exchanger. <br /> • A 1% HP submersible turbine pump (STP), controlled by a dispenser switch <br /> and used to circulate the gasoline through the piping system and to house the <br /> Vaporless LD 3000 leak detector. <br /> • A 30' long X 3%" diameter FRP rigid pipe that led from the pump to the <br /> junction of two branches of large diameter pipes used for the evaluation. One <br /> branch was a 200' long X 4" diameter FRP rigid pipe connected by a 150' <br /> long X 3%" diameter FRP rigid pipe back to the product tank. The other <br /> branch was a 130' long X 3" diameter flexible pipe that ran back to the <br /> product tank. Both branches of piping had valves at the pump end and <br /> dispensing end, allowing them to be isolated from each other or ran <br /> simultaneously. <br /> • Thermocouples were used to measure gasoline temperature. The fuel <br /> temperature in the tank was obtained from the tank gauge that was <br /> permanently installed in the tank. Three thermocouples were used to <br /> measure soil temperature at 2", 4", and 12" from the piping per the EPA <br /> protocol. The product tank temperature and weighted soil temperature were <br /> used to compute the temperature differential. <br /> A length and volume summary of the piping configurations is provided in Table 1. <br /> Table 1. Description of Pipelines Used in This Evaluation <br /> Length-ft (Volume-gal) of Each Pipe Segment <br /> Line Description 3.125" dia 4" dia 3" dia Total Gal. Bulk Modulus <br /> FRP FRP Flex (psi) <br /> Flex Line 30 (12)' 0 130 (48) 48* 8,360 <br /> Evaluation <br /> Rigid Line 180 (72) 200 (131) 0 203 34,458 <br /> Evaluation <br /> Combined Flex & 180 (72) 200 (131) 130 (48) 251 na <br /> Rigid Evaluation <br /> *The National Workgroup does not allow volume of rigid line to be included in flex line <br /> volume for purposes of calculating maximum applicable line size. <br /> Page 2 of 8 <br />