COMPLIANCE INFO_JAN 2011-JUN 2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15237
>
2300 - Underground Storage Tank Program
>
PR0517272
>
COMPLIANCE INFO_JAN 2011-JUN 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 10:41:46 AM
Creation date
6/23/2020 6:59:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
JAN 2011-JUN 2011
RECORD_ID
PR0517272
PE
2361
FACILITY_ID
FA0012979
FACILITY_NAME
FLYING J TRAVEL PLAZA #617
STREET_NUMBER
15237
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
02519014
CURRENT_STATUS
01
SITE_LOCATION
15237 N Thornton Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0517272_15237 N THORNTON_JAN 2011-JUN 2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
316
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C, <br />File MR29667 Page TI -2 of 2 Issued: 2005-09-08 <br />SIMULATED USE RESISTANCE T4 FLUIDS TEST (FIBERGLASS REINFORCED PLASTIC SUMP <br />MATERIALS): <br />One sample - r described in Item B was placedin a container <br />filled with each of the fluids Listed below such that the fittings inside the <br />container were completely covered with the fluids. The samples and fluids <br />were maintained at a temperature of 100*F throughout the exposure. Following <br />30 days in this condition,containersb -• to an internal <br />pressure of 4.5 psig (based on a maximum sump depth of 10.3 ft.) for a period <br />of at least 5 min. while the samples were examined for evidence of leakage. <br />100% Methanol <br />{Methanol/50% ASTM Reference Fuel C <br />15t Ethanol/85% ASTM Reference Fuel C <br />lot Ethanol/90t ASTM Reference Fuel C <br />15% MTBE/85% ASTM Reference Fuel C <br />There was no evidence of leakage <br />SIMULATED USE RESISTANCE TO FLUIDS TEST (FIBERGLASS REINFORCED PLASTIC SUMP <br />One sample assembly as described in Item C was placed in a container <br />filled with each of the fluids Listed below such that the fittings inside the <br />container were completely covered with the fluids. The samples and fluids <br />were maintained at a temperature of 1006F throughout the exposure. Following <br />30 days in this condition, the containers were subjected to an internal <br />pressure of 4.5 psig (based on a maximum sump depth of 10.3 ft.) for a period <br />of at least 5 min, while the samples were examined for evidence of leakage. <br />00' Methanol <br />i Methanol/50% ASTM Reference <br />Ethanol <br />50% Ethanol/50% ASTM Reference Fuel C <br />Ethanol/85% ASTM Reference Fuel C <br />10% Ethanol/901 ASTM Reference Fuel C <br />15% MTBE/85% ASTM Reference Fuel C <br />RESULTS <br />Diversified Products Manufacturing Inc. Approvals for Tech Manual Rev 2 Page 9 of 13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.