Laserfiche WebLink
Appendix VI <br />(Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://w rd E Wn <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California APR 2014 <br />Authority Cited. Chapter 6 7, Health and Safety Code; Chapter 16, Division 3, Tule 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or reporting o <br />monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the ore�� e <br />owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. Hr each HEALTH <br />A. General Information <br />Facility Name: Pacific Bell Telephone Co. dba AT&T California <br />Site Address: 1812 COLEY AVE. City: <br />Facility Contact Person: Dave Dube <br />Make/Model of Monitoring System: Veeder Root TLS -350 plus <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment <br />Tank ID: UGOl0U001 <br />Building No.: UG010 <br />Escalon Zip: 95320 <br />Contact Phone No.: 2091374-4022 <br />Date of Testing/Servicing: 3/26/2014 <br />inspected/serviced: <br />Tank ID: <br />F In -Tank Gauging Probe. Model: <br />In -Tank Gauging Probe. Model: 847390-103/731089 <br />Annular Space or Vault Sensor. Model: 794390420/490104 <br />r Annular Space or Vault Sensor. Model: <br />Piping Sump/ Trench Sensor(s). Model 794380-208/515978 <br />F Piping Sump/ Trench Sensor(s). Model: <br />Fill Sump Sensor(s). Model: <br />F Fill Sump Sensor(s). Model: <br />F Mechanical Line Leak Detector. Model: <br />F Mechanical Line Leak Detector. Model: <br />Electronic Line Leak Detector. Model: <br />F Electronic Line Leak Detector. Model: <br />Tank Overfill / High -Level Sensor. Model: 790091-001 <br />r Tank Overfill / High -Level Sensor. Model: <br />Other (specify equipment type and model in Section E on Page 2). <br />; F Other (specify equipment type and model in Section E on Page 2). <br />Tank ID• <br />Tank ID: <br />F In -Tank Gauging Probe. Model: <br />In -Tank Gauging Probe. Model: <br />Annular Space or Vault Sensor. Model: <br />F Annular Space or Vault Sensor. Model: <br />Piping Sump/ Trench Sensor(s). Model: <br />F Piping Sump/ Trench Sensor(s). Model: <br />Fill Sump Sensor(s). Model: <br />F Fill Sump Sensor(s). Model: <br />Mechanical Line Leak Detector. Model: <br />F Mechanical Line Leak Detector. Model: <br />Electronic Line Leak Detector. Model: <br />F Electronic Line Leak Detector. Model: <br />Tank Overfill / High -Level Sensor. Model: <br />F Tank Overfill / High -Level Sensor. Model: <br />F Other (specify equipment type and model in Section E on Page 2). <br />F Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID <br />Dispenser ID: <br />Dispenser Containment Sensor(s). Model: <br />F Dispenser Containment Sensor(s). Model: <br />Shear Valve(s). <br />F Shear Valve(s). <br />F Dispenser Containment Float(s) and Chain(s). <br />F Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID <br />{ Dispenser ID <br />Dispenser Containment Sensor(s). Model: <br />F Dispenser Containment Sensor(s). Model: <br />F Shear Valve(s). <br />r Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information <br />for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document <br />was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' <br />checklists) necessary to verify that this information is correct and <br />a Plot Plan showing the layout of monitoring equipment For any equipment <br />capable of generating such reports, I have also attached a copy of <br />the report; (check all that apply) : System set-up F Alarm history <br />report <br />Technician Name (print): Victor Guerrero <br />/� "— IN <br />Signature: <br />} <br />Certification No.: B36532 License. No.: 588098 <br />Testing Company Name: TAIT ENVIRONMENTAL SERVICES Phone No.: 714560-8222 <br />Testing Company Address: 2131 soUTHDUPONTEMF ANAMNLCA92806 Date of Testing/Servicing: 3/26/2014 <br />