My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COLEY
>
1812
>
2300 - Underground Storage Tank Program
>
PR0231881
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2022 11:15:56 AM
Creation date
6/23/2020 6:59:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231881
PE
2371
FACILITY_ID
FA0003946
FACILITY_NAME
AT&T California - UG010
STREET_NUMBER
1812
STREET_NAME
COLEY
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22715414
CURRENT_STATUS
01
SITE_LOCATION
1812 Coley Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0231881_1812 COLEY_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
288
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEI VED <br />F. In -Tank Gauging / SIR Equipment: APR 0 9 2014 <br />R_ Check this box if tank gauging is used only for* Nntorr control. <br />F Check this box if no tank gauging or SIR equip <br />This section must be completed if in -tank gauging equipment is used to perform leak detection monitoring. rAVROH 01M83MAR E7MNtTWA L <br />?mplete the foll <br />hecklist <br />....._. __...._._..... __ .......... ._ <br />F Yes <br />r No* <br />Has all input wiring been inspected for proper entry and termination, including testing for ground faults? <br />F Yes <br />F No* <br />Were all tank gauging probes visually inspected for damage and residue buildup? <br />Yes <br />r No* <br />Was accuracy of system product level readings tested? <br />F Yes <br />I— No* <br />Was accuracy of system water level readings tested? <br />Yes <br />F No* <br />Were all probes reinstalled properly? <br />F Yes <br />F No* <br />Were all items on the equipment manufacturer's maintenance checklist completed? <br />*In the Section H, below, describe how and when these deficiencies were or will be corrected. <br />G. Line Leak Detectors (LLD): � Check this box if LLDs are not installed. <br />Complete the following checklist: _ <br />Yes <br />_* <br />�' No <br />Fq to verifyLLD performance?(Check <br />or equipment start-up or annual equipment certification, was a leak simulated <br />• N/A <br />all that apply) Simulated leak rate: F 3 gp.h.; F 0.1 g.p.h ; I— 0.2 g.p.h. <br />Yes <br />No* <br />Were all LLDs confirmed operational and accurate within regulatory requirements? <br />Yes <br />No* <br />Was the testing apparatus properly calibrated? <br />Yes <br />f— No* <br />For mechanical LLDs, does the LLD restrict product flow if it detects a leak? <br />FN/A <br />Yes <br />No* <br />For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? <br />N/A <br />F Yes <br />F No * <br />c s, oes e turne � <br />or electronic LLDdthe turbine <br />Flshut off if any portion of the monitoring system is disabled or <br />F N/A <br />disconnected? <br />r Yes <br />No* <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or <br />N/A <br />fai is a test? <br />F Yes <br />F No* <br />For electronic LLDs, have all accessible wiring connections been visually inspected? <br />N/A <br />Yes No* <br />Were all items on the equipment manufacturer's maintenance checklist completed? i <br />* In the Section <br />IL below, describe how and when these deficiencies were or willbe corrected. <br />H. Comments: <br />System. <br />