My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COLEY
>
1812
>
2300 - Underground Storage Tank Program
>
PR0231881
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2022 11:15:56 AM
Creation date
6/23/2020 6:59:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231881
PE
2371
FACILITY_ID
FA0003946
FACILITY_NAME
AT&T California - UG010
STREET_NUMBER
1812
STREET_NAME
COLEY
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22715414
CURRENT_STATUS
01
SITE_LOCATION
1812 Coley Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0231881_1812 COLEY_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
288
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI <br />(Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at l€tp:;%www.watenfsoards.ca.gov .) <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited. Chapter 6.7, Health and Safety Code, Chapter 16, Division 3, Title 23, California Code ofRegulations <br />This form mustbe used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each <br />monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator <br />owner/operator must submit a copy ofthis form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: Pacific Bell Telephone Co. dba AT&T California Building No.: UG010 <br />Site Address: 1812 COLEY AVE. City: Escalon Zip: 95320 <br />The <br />Facility Contact Person: Gary Chi mienti Contact Phone No.: (925) 468-8103 <br />Make/Model of Monitoring System: Veeder-Root TLS -350 plus Date of Testing/Servicing: 4/11/2013 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced: <br />kGau <br />Tank ID: UG 01OU001 Tank ID: <br />ul <br />Gauging Probe Model. 847390-103/731089 <br />In-TanIn-Tank Gauging Probe. Model. <br />Annular Space or Vault Sensor. Model: 794390-420 / 490104 Annular Space or Vault Sensor. Model: <br />?= r 794380-208 / 515978 <br />ak <br />Piping Sump/ Trench Sensor(s). Model: � � Piping Sump/ Trench Sensor(s). Model: <br />B <br />F Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model:, <br />Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: < <br />Electronic Line Leak Detector. Model: F Electronic Line Leak Detector. Model: <br />i; <br />Tank Overfill/ High -Level Sensor. Model 790091 001 r Tank Overfill/ High -Level Sensor. Model: i <br />Other (specify equipment type and model m Section E on Page 2).Other (specify equipment type and model in Section E on Page 2) <br />iier.'ttr(sper!:rwwn�.:..,ne an..armee. ...e�rel.e..liPa .iii.. rn.i..�arr .R'. >> lt\' .CHa'kFkFk'YS''��/�.\ �... `S'v°Y:.�G `«L�., `�1�,'3`hSnC`1�?�.+$k%?8'� )fNii�/.i£�✓?.�'. /. <br />Tank ID: i Tank ID: k <br />In -Tank Gauging Probe. Model: F In-TankGauging Probe. Model: <br />F. <br />1, F Annular Space or Vault Sensor. Model: r Annular Space or Vault Sensor. Model: <br />i? F Piping Sump/ Trench Sensor(s). Model: F Piping Sump/ Trench Sensor(s). Model: <br />F Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br />: <br />F Mechanical Line Leak Detector. Model: F Mechanical Line Leak Detector. Model: <br />F Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br />r€ F Tank Overfill/ High -Level Sensor. Model: F Tank Overfill / High -Level Sensor. Model: <br />F Other (specify equipment type and model m Section E on Page 2) F Other (specify equipment type and model m Section E on Page 2) <br />... <br />� <br />Dispenser ID: <br />Dispenser <br />p ID: <br />P r Dispenser Containment Sensor(s). Model: F Dispenser Containment Sensmr s). Model: <br />i <br />F Shear Valve(s). r Shear Valve(s). <br />F Dispenser Containment Float(s) and Chain(s) F Dispenser Containment Float(s) and Chain(s) <br />Dispenser ID: i Dispenser ID: <br />_F Dispenser ContainmentSensogs). Model. �F Dispenser Containment Sen sor(s). Model: l <br />Shear Valve(s). F Shear Valve(s). <br />Dispenser Containment Float(s) and Cham(s). t F Dispenser Containment Float(s) and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e g. manufacturers' checklists) necessary to verify that this information is correctand <br />a Plot Plan showing the layout of monitoring equipment For any equipment capable of generating such reports, I have also attached a copy of <br />the report; (check all that apply) : System set-up Alarm history report <br />Technician Name (print): John Cascio_Cz: <br />Signature: -01 <br />Certification No.: B35337 License. No.: 588098 <br />Testing Company Name: TAIT ENVIRONMENTAL SERVICES Phone No.: 714560-8222 <br />Testing Company Address: 2131 soUr'HDnJPONTDMV$ANAHEI-NtCA92806 Date of Testing/Sery icing: 4/11/2013 <br />
The URL can be used to link to this page
Your browser does not support the video tag.