My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COLEY
>
1812
>
2300 - Underground Storage Tank Program
>
PR0231881
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2022 11:15:56 AM
Creation date
6/23/2020 6:59:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231881
PE
2371
FACILITY_ID
FA0003946
FACILITY_NAME
AT&T California - UG010
STREET_NUMBER
1812
STREET_NAME
COLEY
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22715414
CURRENT_STATUS
01
SITE_LOCATION
1812 Coley Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0231881_1812 COLEY_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
288
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E. Comments: <br />er Sensors from Page 1: <br />Vent Sump Sensor - 794380-208 -515989 -Certified <br />Transition Sump Sensor - 794380-208 -514107 -Certified <br />- Inside Piping Pan Sensor - 794390-420 -793173 -Certified <br />Overfill Prevention Valve is Located in The Drop Tube. <br />D. Results of Testing/Servicing <br />Software Version Installed: 120.00 <br />Complete the following checklist: <br />ellll <br />Yes <br />N o* <br />Is the audibl e ala rm operational? <br />`' Yes <br />No* <br />Is the visual alarm operational? <br />........, _,.... _. ,., <br />Yes <br />No* <br />,m , ;... <br />Were all sensors visually inspected, functionally tested, and confimned operational <br />,. <br />Yes <br />I No * <br />Were all sensors i nstalled at lowest point of secondary containment and p osrtiouedso that other equipment <br />will not interfere with their <br />groper operation'? <br />dWW�\qWS :3,'<a xx-: e \� �W.WWIW <br />IF"Yes <br />"� <br />No* <br />\\\R�\\\ ,\`.k• MW �.AW'L,,. NO. . "0:1 �`�8• Y�•'.��`"�%�.::� ^�/,,,4Y,.�U" .;. <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />N/A <br />operational? <br />'.�• .., �'? ;:.:......` �:\:�• C�-�, `'A r`��. SM,�SKQK6l'.:7*"�A"4.. `d'.f'�:^ .��CC'r1.)`�WiYc ok ... :.:(ZIKKt,.\"`,4`v k... �h�h. ',:,.,�u1C..:� .. .�. .. •:'.,�^�k,4v3>»S•.::.QD�aio"'�"'??.cY<.�zi�".... <br />No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary <br />containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which_ <br />N/A <br />sensors initiate positive shut-down? (Check all that apply) I <br />Sump/Trench Sensors; F Dispenser Containment Sensors. Didyou confirm positive shut-down <br />Iduetoleaks <br />and sensor failure/disconnection? <br />Yes r No. <br />Yes =; <br />No* <br />( Fortank systems that utilize themonitoring system as theprimary tank overfill warning device (i.e. no <br />;mechanical overfill prevention valve is installed), is the overfill warning alarm vi sible and audible at the; <br />=(F <br />i <br />N/A <br />;tank fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? <br />E <br />ij <br />F Yes* <br />No <br />�= Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment <br />replaced and list the manufacturer name and model for all replacement parts in Section E below. <br />f Yes* <br />v No <br />Was liquid found inside an secondary y gn y y (Check all that <br />q y containments stems designed as dr systems? Ch <br />apply) F Product Water. If yes describe causes in Section E below. <br />F Yes ii <br />F No* <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set up report~ if applicable F <br />Yes <br />No* <br />�Is all monitoring equipment operational per manufacturers specifications? <br />F <br />_,_.. <br />_..... _.... ........ <br />* In Section E below, describe how and when these deficiencies were or will be corrected <br />E. Comments: <br />er Sensors from Page 1: <br />Vent Sump Sensor - 794380-208 -515989 -Certified <br />Transition Sump Sensor - 794380-208 -514107 -Certified <br />- Inside Piping Pan Sensor - 794390-420 -793173 -Certified <br />Overfill Prevention Valve is Located in The Drop Tube. <br />