My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EIGHTH
>
717
>
2300 - Underground Storage Tank Program
>
PR0522448
>
COMPLIANCE INFO_2002-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2024 4:47:24 PM
Creation date
6/23/2020 6:59:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2006
RECORD_ID
PR0522448
PE
2371
FACILITY_ID
FA0015274
FACILITY_NAME
SHELL I-5
STREET_NUMBER
717
Direction
W
STREET_NAME
EIGHTH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16314045
CURRENT_STATUS
01
SITE_LOCATION
717 W EIGHTH ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0522448_717 W EIGHTH_2002-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
404
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S WRCB,January 2002 Page of <br /> 8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sums ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑Sump Manufacturer ,ixj„Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum 004ydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: Equipment Resolution: <br /> Fill Sume# Lt Fill S imp# Fill Sump# Fill Sume# <br /> Sump Diameter: t " <br /> Height from Tank Top to Top of ®� e <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest c7"J ( <br /> Electrical Penetration: <br /> Condition of sump prior to <br /> testing: <br /> Portion of Sump Tested <br /> Sump Material: <br /> Wait time between applying Gl/ C7 <br /> pressure/vacuum/water and <br /> starting test: <br /> Test Start Time: <br /> Initial Reading(RI): <br /> Test End Time: l Z,•at <br /> Final Reading(RF): <br /> Test Duration: <br /> Change in Reading(RF-R,): Q <br /> Pass/Fail Threshold or Criteria: <br /> Test Result: XPass ❑Fail J&Pass ❑Fail krPass ❑Fail ❑ Pass ❑Fail <br /> Is there a sensor in the sump? es ❑No es ❑No es ❑No ❑Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is ,8(Ves ❑No ❑NA KYes ❑No ❑NA <Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> detected? <br /> Was sensor removed for testing? , Yes ❑No ❑NA XYes ❑No ❑NA es ❑No ❑NA ❑Yes u No NA <br /> Was sensor properly replaced and yes ❑No ❑NA 'Yes ElNo El NA , 'Yes ❑No El =Yes NA ❑NA <br /> verified functional after test in ? <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> t <br />
The URL can be used to link to this page
Your browser does not support the video tag.