ACCESSIBILITY/CBC Notes ACCESSIBILITY/CBC Notes (Continued) ACCESSIBILITY/CBC Notes (Continued)
<br /> SIGNS tactile characters shall be located so that a clear floor space of 18 inches minimum by 18 inches
<br /> minimum, centered on the tactile characters, is provided beyond the arc of any door swing between the H. BUILT-IN ELEMENTS
<br /> 1. Except building directories, menus, seat and row designations in assembly areas, occupant names, building closed position and 45 degree open position. Where permanent identification signage is provided for
<br /> addresses, and company names and logos, new or altered signs shall be provided in accordance with rooms and spaces they shall be located on the approach side of the door as one enters the room or DINING SURFACES AND WORK SURFACES
<br /> 11 B-216 Signs and shall comply with 11 B-703 Signs. The addition of or replacement of signs shall not space. Signs that identify exits shall be located on the approach side of the door as one exits the room or
<br /> trigger any additional path of travel requirements. §11 B-216.1 space. 1. Dining surfaces and work surfaces shall comply with 11 B-902.2 and 11 B-902.3.
<br /> 2. Interior and exterior signs identifying permanent rooms and spaces shall comply with 11 B-703.1 General, 2. A clear floor space complying with 11 B-305 positioned for a forward approach shall be provided. Knee and toe
<br /> 11 B-703.2 Raised Characters, 11 B-703.3 Braille and 11 B-703.5 Visual Characters. Where pictograms are 21. Visual characters shall comply with the following, except where visual characters comply with 11 B-703.2 clearance complying with 11 B-306 shall be provided.
<br /> provided as designations of permanent interior rooms and spaces,the pictograms shall comply with Raised Characters and are accompanied by Braille complying with 11 B-703.3 Braille, they shall not be 3. The tops of dining surfaces and work surfaces shall be 28 inches minimum and 34 inches maximum above
<br /> 11 B-703.6 Pictograms and shall have text descriptors complying with 11 B-703.2 and 11 B-703.5. §11 B-216.2 required to comply with 11 B-703.5.2 through 11 B-703.5.6, 11 B-703.5.8 and 11 B-703.5.9: the finish floor or ground.
<br /> (See exception) a. Characters and their background shall have a non-glare finish. Characters shall contrast with their 4. Accessible dining surfaces and work surfaces for children's use shall comply with 11 B-902.4.
<br /> 3. Signs that provide direction to or information about interior and exterior spaces and facilities of the site shall background with either light characters on a dark background or dark characters on a light background. 5. Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating
<br /> comply with 11 B-703.5 Visual Characters. §11 B-216.3 b. Characters shall be uppercase or lowercase or a combination of both. spaces and standing spaces at the dining surfaces shall comply with 11 B-902. In addition,where work ©2020 STARBUCKS COFFEE COMPANY
<br /> 4. Signs for means of egress shall comply with 11 B-216.4 Means of Egress: c. Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, surfaces are provided for use by other than employees, at least 5 percent shall comply with 11 B-902.
<br /> a. Signs required by Chapter 10, Section 1011.4 at doors to Doors at exit passageways, exit discharge, and or of other unusual forms. 6. Dining surfaces and work surfaces required to comply with 11 B-902 shall be dispersed throughout the space
<br /> exit stairways shall be identified by tactile signs complying comply with 11 B-703.1 General, 11 B-703.2 d. Characters shall be selected from fonts where the width of the uppercase letter"O" is 55-60% minimum or facility containing dining surfaces and work surfaces for each type of seating in a functional area. Work STARBUCKS
<br /> Raised Characters, 11 B-703.3 Braille and 11 B-703.5 Visual Characters. §11 B-216.4.1 and 110 percent maximum of the height of the uppercase letter"I". surfaces required to comply with 11 B-902 shall be dispersed throughout the space or facility containing work 2401 UTAH AVENUE SOUTH
<br /> b. Signs required by section 1003.2.13.5.4 of the International Building Code (2000 edition) or section e. Minimum character height shall comply with Table 11 B-703.5.5. Viewing distance shall be measured as surfaces.
<br /> 1007.6.4 of the International Building Code (2003 edition) (incorporated by reference, see"Referenced the horizontal distance between the character and an obstruction preventing further approach towards 7. Where food or drink is served for consumption at a counter exceeding 34 inches in height, a portion of the SEATTLE, WASHINGTON 98134
<br /> Standards"in Chapter 1) Chapter 10, Section 1007.11 to provide instructions in areas of refuge shall the sign. Character height shall be based on the uppercase letter"I". main counter 60 inches minimum in length shall be provided in compliance with 11 B-902.3. (206) 318-1575
<br /> comply with 11 B-703.5 Visual Characters. Signs required by Chapter 10, Section 1007.9 at doors to f. Visual characters shall be 40 inches minimum above the finish floor or ground. 8. Food service lines shall comply with 11 B-904.5. Where self-service shelves are provided, at least 50 percent,
<br /> areas of refuge and exterior areas for assisted rescue shall comply with 11 B-703.1 General, 11 B-703.2 g. Stroke thickness of the uppercase letter"I"shall be 10 percent minimum and 20 percent maximum of the but no fewer than one, of each type provided shall comply with 11 B-308. THESE DRAWINGS AND THE PROJECT MANUAL
<br /> Raised Characters, 11 B-703.3 Braille and 11 B-703.5 Visual Characters and include an International height of the character. 9. Queues and waiting lines servicing counters or check-out aisles required to comply with 11 B-904.3 or ARE CONFIDENTIAL AND SHALL REMAIN THE
<br /> Symbol of Accessibility (ISA) complying with 11 B-703.7.2.1 ISA. §11 B-216.4.2 h. Character spacing shall be measured between the two closest points of adjacent characters, excluding 11 B-904.4 shall comply with 11 B-403. SOLE PROPERTY OF STARBUCKS
<br /> c. Signs required by section 1003.2.13.6 of the International Building Code (2000 edition) or section 1007.7 word spaces. Spacing between individual characters shall be 10 percent minimum and 35 percent 10. Counters in food service lines shall comply with 11 B-904.5. CORPORATION, WHICH IS THE OWNER OF THE
<br /> of the International Building Code (2003 edition) (incorporated by reference, see"Referenced Standards" maximum of character height. a. Self-service shelves and dispensing devices for tableware, dishware, condiments, food and beverages COPYRIGHT IN THIS WORK. THEY SHALL NOT
<br /> in Chapter 1) Chapter 10, Section 1007.10 to provide directions to accessible means of egress shall i. Spacing between the baselines of separate lines of characters within a message shall be 135 percent shall comply with 11 B-308. BE REPRODUCED (IN WHOLE OR IN PART),
<br /> comply with 11 B-703.5 Visual Characters. §11 B-216.4.3 minimum and 170 percent maximum of the character height. SHARED WITH THIRD PARTIES OR USED IN ANY
<br /> d. Signs required by Chapter 10, Section 1008.1.9.7, item 5.1 at doors with delayed egress locks shall j. Text shall be in a horizontal format. CHECK-OUT AISLES AND SALES AND SERVICE COUNTERS MANNER ON OTHER PROJECTS OR
<br /> comply with 11 B-703.1 General, 11 B-703.2 Raised Characters, 11 B-703.3 Braille and 11 B-703.5 Visual 22. Symbols of accessibility and their background shall have a non-glare finish. Symbols of accessibility shall EXTENSIONS TO THIS PROJECT WITHOUT THE
<br /> Characters. §11 B-216.4.4 contrast with their background with either a light symbol on a dark background or a dark symbol on a light 17. Where provided, check-out aisles, sales counters, service counters, food service lines, queues, and waiting PRIOR WRITTEN CONSENT OF STARBUCKS
<br /> 5. Parking spaces complying with 11 B-502 Parking Spaces shall be identified by signs complying with background. §11 B-703.7.1 lines shall comply with 11 B-227 and 11 B-904. CORPORATION. THESE DRAWINGS AND
<br /> 11 B-502.6 Identification. §11 B-216.5 25. Symbols shall comply with the following: 18. All portions of counters required to comply with 11 B-904 shall be located adjacent to a walking surface SPECIFICATIONS ARE INTENDED TO EXPRESS
<br /> 6. In residential facilities,where parking spaces are assigned to specific residential dwelling units, identification a. The International Symbol of Accessibility shall comply with Figure 11 B-703.7.2.1 ISA.The symbol shall complying with 11 B-403. DESIGN INTENT FOR A PROTOTYPICAL
<br /> of accessible parking spaces shall not be required. consist of a white figure on a blue background. The blue shall be Color No. 15090 in Federal Standard 19. Sales counters and service counters shall comply with either of the following and the accessible portion of the STARBUCKS STORE (WHICH IS SUBJECT TO
<br /> 7. In existing buildings and facilities where not all entrances comply with 11 B-404 Doors, Doorways, and Gates, 5958. §11 B-703.7.2.1 (See exception) counter to shall extend the same depth as the sales or service counter to
<br /> o2S p p p• CHANGE AT ANYTIME) AND DO NOT REFLECT
<br /> CD compliant entrances shall be identified by the International Symbol of Accessibility(ISA) complying with b. The International Symbol of TTY shall comply with Figure 11 B-703.7.2.2. a. A portion of the counter surface that is 36 inches long minimum and 34 inches high maximum above the ACTUAL SITE CONDITIONS. NEITHER PARTY
<br /> = 11 B-703.7.2.1 ISA. Directional signs complying with 11 B-703.5 Visual Characters that indicate the location of c. Telephones with a volume control shall be identified by a pictogram of a telephone handset with radiating finish floor shall be provided. A clear floor or ground space complying with 11 B-305 shall be positioned for SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
<br /> the nearest entrance complying with 11 B-404 shall be provided at entrances that do not comply with 11 B-404 sound waves on a square field such as shown in Figure 11 B-703.7.2.3. a parallel approach adjacent to the 36 inch minimum length of counter. THE OTHER (EXCEPT STATED ABOVE) UNTIL A
<br /> Doors, Doorways, and Gates. Directional signs complying with 11 B-703.5 Visual Characters, including the d. Assistive listening systems shall be identified by the International Symbol of Access for Hearing Loss b. A portion of the counter surface that is 36 inches long minimum and 34 inches high maximum shall be WRITTEN AGREEMENT IS FULLY EXECUTED BY
<br /> ISA complying with 11 B-703.7.2.1 ISA, indicating the accessible route to the nearest accessible entrance complying with Figure 11 B-703.7.2.4. provided. Knee and toes ace complyingwith 11 B-306 shall be provided under the counter.A clear floor
<br /> W p P BOTH PARTIES.
<br /> shall be provided at junctions when the accessible route diverges from the regular circulation path. e. Rooms, facilities and paths of travel that are accessible to and usable by people who are adversely or ground space complying with 11 B-305 shall be positioned for a forward approach to the counter.
<br /> co §11 B-216.6 (See exceptions) impacted by airborne chemicals or particulate(s) and/or the use of electrical fixtures and/or devices shall 20. Where provided, at least one of each type of sales counter and service counter shall comply with 11 B-904.4. STARBUCKS TEMPLATE VERSION: 12020.10.23
<br /> N 8. Where existing elevators do not comply with 11 B-407 Elevators, compliant elevators shall be clearly be identified by the Cleaner Air Symbol complying with Figure 11 B-703.7.2.5. This symbol is to be used Where counters are dispersed throughout the building or facility, counters complying with 11 B-904.4 also shall
<br /> o identified with the International Symbol of Accessibility (ISA) complying with 11 B-703.7.2.1 ISA. Existing strictly for publicly funded facilities or any facilities leased or rented by state of California, not be dispersed.
<br /> N buildings that have been remodeled to provide specific elevators for public use that comply with these concessionaires. The symbol, which shall include the text"Cleaner Air"as shown, shall be displayed 21. Queues and waiting lines servicing counters or check-out aisles required to comply with 11 B-904.3 or
<br /> building standards shall have the location of and the directions to these elevators posted in the building lobby either as a negative or positive image within a square that is a minimum of 6 inches on each side.The 11 B-904.4 shall comply with 11 B-403.
<br /> rn on a sign complying with 11 B-703.5 Visual Characters, including the ISA complying with 11 B-703.7.2.1 ISA. symbol may be shown in black and white or in color. When color is used, it shall be Federal Blue (Colorarchitectureand _
<br /> riors
<br /> rl_ 11 B-216.7 No. 15090 Federal Standard 5956 on white, or white on Federal Blue.There shall be at least a 70-
<br /> § ) RESTAURANT, CAFETERIAS, BANQUET FACILITIES, BARS, PERFORMANCE AREAS. PRESS BOXES,
<br /> 9. Identification and directional signs for public TTYs shall be provided in accordance with 11 B-216.9 TTYs. percent color contrast between the background of the sign from the surface that it is mounted on. EMPLOYEE AREAS.
<br /> §11 B-216.9 f. Edges of signs shall be rounded, chamfered or eased. Corners of signs shall have a minimum radius of
<br /> a. Public TTYs shall be identified by the International Symbol of TTY complying with 11 B-703.7.2.2 '/8 inch. 1. Within a site.At least one accessible route shall connect accessible buildings, accessible facilities, accessible 5858 Wilshire Blvd #200 T: 323.954.8996
<br /> International Symbol of TTY. §11 B-216.9.1 g. Pole-supported pedestrian traffic-control buttons shall be identified with color coding consisting of a elements, and accessible spaces that are on the same site. §116-206.2.2
<br /> b. Directional signs indicating the location of the nearest public TTY shall be provided at all banks of public textured horizontal yellow band 2 inches in width encircling the pole, and a 1-inch-wide dark border band 2. Entrances shall be provided in accordance with Section 11B-206.4. Entrance doors, doorways, and gates os Angeles, CA 90036 F: 323.954.8965
<br /> pay telephones not containing a public TTY. In addition,where signs provide direction to public pay above and below this yellow band. shall comply with Section 11B-404 and shall be on an accessible route complying with Section 11B-402. www.valerioinc.com , info@valerioinc.com
<br /> telephones,they shall also provide direction to public TTYs. If a facility has no banks of telephones,the §11B-206.4
<br /> directional signage shall be provided at the entrance or in a building directory. Directional signs shall 3. Toilet rooms and bathing rooms. Where toilet rooms are provided, each toilet room shall comply with Section
<br /> o comply with 11 B-703.5 and shall include the International Symbol of TTY complying with 11 B-703.7.2.2. 118 603. Where bathing rooms are provided, each bathing room shall comply with Section 118 603.
<br /> §11 B 216.9.2 G. SPECIAL ROOMS, SPACES, AND ELEMENTS §11 B-213.2
<br /> 14. Each assembly area required by 11 B-219 Assistive Listening Systems to provide assistive listening systems 4. Scope. All areas of newly designed and newly constructed buildings and facilities and altered portions of
<br /> shall provide signs informing patrons of the availability of the assistive listening system. The sign shall AR
<br /> existing buildings and facilities shall comply with these requirements. §11B-201.1 � C�
<br /> � include wording that states"Assistive-Listening System Available"and shall be posted in a prominent place KITCHEN, KITCHENETTES AND WET BARS yo vA
<br /> 5. In restaurants, cafeterias, banquet facilities, bars, and similar facilities, an accessible route shall be provided � o
<br /> N at or near the assembly area entrance. Assistive listening signs shall comply with 11 B-703.5 Visual to all functional areas, including raised or sunken areas, and outdoor areas. §11 B-206.2.5 W SOL LIC.NO.
<br /> Characters and shall include the International Symbol of Access for Hearing Loss complying with 1. Dimension 40 inch minimum clearance between counters, appliances, or cabinets in pass through kitchens. U z o n
<br /> i 6. Where a circulation path directly connects a performance area to an assembly seating area, an accessible c 24228
<br /> 11 B- . . . ssisve Listening Systems. § - . (See exception) ass through shall two entries. § -80 .2.1 a
<br /> Q 703724 AtiLiiSt11 B21610StiPhh kihhll hi11 B4
<br /> route shall directly connect the assembly seating area with the performance area. An accessible route shall EXPIRES
<br /> 2. Dimension 60 inch minimum clearance between opposing base cabinets, counter tops, appliances, or walls s z-31-21
<br /> 15. Where more than one check-out aisle is provided, check-out aisles complying with 11 B-904.3 Check-Out be provided from performance areas to ancillary areas or facilities used by performers unless exempted by Tq �
<br /> Aisles shall be identified by a sign complying with 11 B-904.3.4 Identification Sign. Where check-out aisles are in U-shaped kitchens. §11 B-804.2.2 11 B-206.2.3 Multi-Story Buildings and Facilities, (See exceptions 1 through 7). §11 B-206.2.6 OPCALV��
<br /> U identified by numbers, letters, or functions, signs identifying check-out aisles complying with 11 B-904.3 7. Press boxes in assembly areas shall be on an accessible route. §11 B-206.2.7(See exceptions)
<br /> o Check-Out Aisles shall be located in the same location as the check-out aisle identification. §11 B-216.11 8. Common use circulation paths within employee work areas shall comply with 11 B-402 Accessible Routes.
<br /> rn
<br /> r- (See exception) 3. In residential dwelling units required to comply with 11 B-809 Residential Dwelling Units, at least one 30 inch §11 B-206.2.8(See exceptions)
<br /> N 16. Where Cleaner Air Symbols are provided, they shall comply with 11 B-216.13 Cleaner Air Symbol. wide minimum section of counter shall provide a kitchen work surface that complies with the following: 9. At dining and work surfaces required to be accessible, knee clearance shall be provided that is 30 inches in
<br /> U) 17. Signs shall comply with 11 B-703 Signs. Where both visual and tactile characters are required, either one sign §11 B-804.3 width at 27 inches above the finish floor or ground for a depth of at least 19 inches. §1113-306.3
<br /> 0 with both visual and tactile characters, or two separate signs, one with visual, and one with tactile characters, a. A 30 inch wide b 48 inch dee forward approach clear floors ace shall be provided. The clear floor
<br /> U p 9 Y p pp p
<br /> cY) shall be provided: space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying DINING SURFACES,WORK SURFACES AND BAR
<br /> C) a. Signs as specified in Section 11 B-703 Signs, or in other sections of this code, when included in the with 11 B-306 Knee and Toe Clearance.
<br /> o construction of new buildings or facilities, or when included, altered or replaced due to additions, EXCEPTION:Cabinetry shall be permitted provided all of the following are met: 10. Dining surfaces and work surfaces shall comply with 11 B-902.2 and 11 B-902.3. (See exception)
<br /> rn alterations or renovations to existing buildings or facilities, and when a permit is required, shall comply i. the cabinetry can be removed without removal or replacement of the kitchen work surface;
<br /> r_ 11. A clear floor space complying with 11 B-305 positioned for a forward approach shall be provided. Knee and toe
<br /> N with 11 B-703.1.1.1 Plan Review and 11 B-703.1.1.2 Inspection. ii. the finish floor extends under the cabinetry; and
<br /> clearance complying with 11 B-306 shall be provided. §11 B-902.2
<br /> CE b. Plans, specifications or other information indicating compliance with these regulations shall be submitted iii. the walls behind and surrounding the cabinetry are finished.
<br /> CZ to the enforcing agency for review and approval. b. The kitchen work surface shall be 34 inches maximum above the finish floor or ground. 12. The tops of dining surfaces and work surfaces shall be 28 inches minimum and 34 inches maximum above
<br /> _> c. Signs and identification devices shall be field inspected after installation and approved by the enforcing EXCEPTION:A counter that is adjustable to provide a kitchen work surface at variable heights, 29 the finish floor or ground. 902.3
<br /> LO agency prior to the issuance of a final certificate of occupancy per Chapter 1, Division II, Section 111, or inches minimum and 36 inches maximum, shall be permitted. 13. Accessible dining surfacess and
<br /> work surfaces for children's use shall comply with 11 B-902.4. §11 B-902.4
<br /> final approval where no certificate of occupancy is issued. The inspection shall include, but not be limited c. There shall be no sharp or abrasive surfaces under the work surface counters. (See exception) Q
<br /> to,verification that Braille dots and cells are properly spaced and the size, proportion and type of raised 4. Sinks shall comply with 11 B-606 Lavatories and Sinks. 11 B-804.4 14. Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating
<br /> °� p p Y P p P Yp p Y spaces and standing spaces at the dining surfaces shall comply with 11 B-902. In addition, where work LO
<br /> characters are in compliance with these regulations. 5. At least 50 percent of shelf space in storage facilities shall comply with 11 B-811 Storage. 11 B- 804.5 p g p g p y
<br /> _� 18. Raised characters shall comply with 11 B-703.2 Raised Characters and shall be duplicated in Braille 6. Kitchen appliances shall comply with the following: §11 B-804.6 surfaces are provided for use by other than employees, at least 5 percent shall comply with 11 B-902. cr N z
<br /> complying with 11 B-703.3 Braille. Raised characters shall be installed in accordance with 11 B-703.4 a. A clear floor or ground space complying with 11 B-305 Clear Floor or Ground space shall be provided at §11 excel L
<br /> } Installation Height and Location. each kitchen appliance. Clear floor or ground spaces shall be permitted to overlap. (See exceptions) Q6 Q cy) O
<br /> a. Raised characters shall be 1/32 inch minimum above their background. b. All appliance controls shall comply with 11 B-309 Operable Parts. (See exceptions) 15. Dining surfaces and work surfaces required to comply with 11 B-902 shall be dispersed throughout the space U
<br /> P or facility containing dining surfaces and work surfaces for each type of seating in a functional area. Work Q
<br /> iu b. Characters shall be uppercase. c. Clear floor or ground space shall be positioned adjacent to the dishwasher door. The dishwasher door, in Y 9 g Yp g W
<br /> c. Characters shall be sans serif. Characters shall not be italic, oblique, script, highly decorative, or of other the open position, shall not obstruct the clear floor or ground space for the dishwasher or the sink. surfaces required to comply with 11 B-902 shall be dispersed throughout the space or facility containing work J U) >- (� z
<br /> U unusual forms. d. At the range or cooktop,where a forward approach is provided, the clear floor or ground space shall surfaces. §11 B-226.2 U) -
<br /> z d. Characters shall be selected from fonts where the width of the uppercase letter"O" is 55-60ercent provide knee and toe clearance complyingwith 11 B-306. Where knee and toes ace is provided,the 16. Where food or drink is served for consumption at a counter exceeding 34 inches in height, a portion of the LU -
<br /> XI minimum and 110 percent maximum of the height of the uppercase letter"I". p underside of the range or cooktop shall be insulated or otherwise configured to prevent burns, abrasions, main counter 60 inches minimum in length shall be provided in compliance with 11 B-902.3. §11 B-226.3 L Q z Z
<br /> ooe. Character height measured vertically from the baseline of the character shall be 5/8 inch minimum and 2 or electrical shock. The location of controls shall not require reaching across burners. 17. Food service lines shall comply with 11 B-904.5. Where self-service shelves are provided, at least 50 percent, Q E O Q
<br /> � inches maximum based on the height of the uppercase letter"I". e. Ovens shall comply with the following: but no fewer than one, of each type provided shall comply with 11 B-308. §11 B-227.4 z Q F___ O
<br /> T__ f. Stroke thickness of the uppercase letter"I"shall be 15 percent maximum of the height of the character. i. Side-hinged door ovens shall have the work surface required by 11 B-804.3 Kitchen and Work 18. Queues and waiting lines servicing counters or check-out aisles required to comply with 11 B-904.3 or T
<br /> r g. Character spacing shall be measured between the two closest points of adjacent raised characters Surfaces positioned adjacent to the latch side of the oven door. 11 B-904.4 shall comply with 11 B-403. §11 B-227.5
<br /> N within a message, excluding word spaces. Where characters have rectangular cross sections, spacing ii. Bottom-hinged door ovens shall have the work surface required by 11 B-804.3 Kitchen and Work 19. Counters in food service lines shall comply with 11 B-904.5. §11 B-904.5 Lu 0 LU O O z
<br /> between individual raised characters shall be 1/8 inch minimum and 4 times the raised character stroke Surfaces positioned adjacent to one side of the door. a. Self-service shelves and dispensing devices for tableware, dishware, condiments, food and beverages p p O Q
<br /> � width maximum. Where characters have other cross sections, spacing between individual raised iii. Ovens shall have controls on front panels. shall comply with 11 B-308. §11B-904.5.1 Ir i i 1 121: r
<br /> N characters shall be 1/16 inch minimum and 4 times the raised character stroke width maximum at the f. Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches b. The tops of tray slides shall be 28 inches minimum and 34 inches maximum above the finish floor or 0- I.J.J (n (n
<br /> �2 base of the cross sections, and 1/8 inch minimum and 4 times the raised character stroke width maximum above the finish floor or ground. The clear floor or ground space shall be positioned for a ground. §11 B-904.5.2
<br /> 0 maximum at the top of the cross sections. Characters shall be separated from raised borders and parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or 20. Sales counters and service counters shall comply with either of the following and the accessible portion of the STORE #: 9287
<br /> aD decorative elements 3/8inch minimum. ground space offset 24 inches maximum from the centerline of the dedicated space. counter top shall extend the same depth as the sales or service counter top. §11 B-904.4(See exception)
<br /> 2 h. Spacing between the baselines of separate lines of raised characters within a message shall be 135 7. Sinks. Where sinks are provided, at least 5 percent, but no fewer than one, of each type provided in each a. A portion of the counter surface that is 36 inches long minimum and 34 inches high maximum above the PROJECT #: 23544-077
<br /> n percent minimum and 170 percent maximum of the raised character height. accessible room or space shall comply with Section 11 B-606. finish floor shall be provided. A clear floor or ground space complying with 11 B-305 shall be positioned for ISSUE DATE: 03-12-21
<br /> N i. Text shall be in a horizontal format. a. Mop, service or scullery sinks shall not be required to comply with Section 1113-212.3. (See exception) a parallel approach adjacent to the 36 inch minimum length of counter. §11 B-904.4.1 (See exception) or
<br /> 0 19. Braille shall be contracted (Grade 2) and shall comply with 11 B-703.3 Braille and 11 B-703.4 Installation b. Scrub sinks, as defined in California Plumbing Code Section 221.0, shall not be required to comply with b. A portion of the counter surface that is 36 inches long minimum and 34 inches high maximum shall be SR. DESIGN MANAGER: JESSICA RAMOS
<br /> N Height and Location: Section 11 B-606. (See exception) provided. Knee and toe space complying with 11 B-306 shall be provided under the counter. A clear floor DESIGN MANAGER: JESSICA RAMOS
<br /> a. Braille dots shall have a domed or rounded shape and shall comply with Table 11 B-703.3.1.The or ground space complying with 11 B-305 shall be positioned for a forward approach to the counter. CHECKED BY: LILY JUMANAN
<br /> indication of an uppercase letter or letters shall only be used before the first word of sentences, proper GENERAL EXCEPTIONS §11 B-904.4.2
<br /> p nouns and names, individual letters of the alphabet, initials, and acronyms.
<br /> b. Braille shall be positioned below the corresponding text in a horizontal format,flush left or centered. If 1. Spaces and elements within employee work areas shall be designed and constructed so that individuals with Revision Schedule
<br /> text is multi-lined, Braille shall be placed below the entire text. Braille shall be separated 3/8 inch disabilities can approach, enter, and exit the employee work area. §11 B-203.9
<br /> Qminimum and 1/2 inch maximum from any other tactile characters and 3/8 inch minimum from raised 2. Spaces and elements within employee work areas shall have common use circulation paths that comply with Rev Date By Description
<br /> borders and decorative elements. all applicable requirements of Division 4 Accessible Routes. §11 B-203.9 02-26-21 WY CHECK SET
<br /> CZ CZ 20. Signs with tactile characters shall comply with 11 B-703.4 Installation Height and Location. §11 B-703.4 3. Spaces and elements within employee work areas shall have accessible means of egress in accordance with 03-12-21 WY PERMIT SET
<br /> a. Tactile characters on signs shall be located 48 inches minimum above the finish floor or ground surface, Chapter 10, Section 1007. §11 B-203.9
<br /> measured from the baseline of the lowest tactile character Braille cells and 60 inches maximum above 4. Where employee work areas have audible alarm coverage, the wiring system shall be designed so that
<br /> the finish floor or ground surface, measured from the baseline of the highest tactile character line of visible alarms complying with Chapter 9, Section 907.5.2.3.2 can be integrated into the alarm system.
<br /> raised characters. §11 B-703.4.1 (See exception) §11 B-203.9, §11 B-215.3
<br /> b. Where a tactile sign is provided at a door,the sign shall be located alongside the door at the latch side.
<br /> Where a tactile sign is provided at double doors with one active leaf, the sign shall be located on the SHEET TITLE:
<br /> inactive leaf. Where a tactile sign is provided at double doors with two active leafs, the sign shall be ADA NOTES
<br /> n located to the right of the right hand door. Where there is no wall space at the latch side of a single door
<br /> C0 or at the right side of double doors, signs shall be located on the nearest adjacent wall. Signs containing
<br /> C) SCALE: PN/A,HOWN
<br /> T-_ SHEET NUMBER:
<br /> N
<br /> N
<br /> r
<br /> co
<br /> 031