Laserfiche WebLink
Regulatory Cross Reference Version :27.10.4 <br /> I CFR Part 265.50 <br /> §265.50 -56 BRIEF DESCRIPTION LOCATION IN <br /> PLAN <br /> §265.54 - <br /> (c) The facility changes in its design, construction, operation, § 1.4 - Plan <br /> maintenance, or other circumstances in a way that materially Review and <br /> increases the potential for fires, explosions, or releases of Update <br /> hazardous waste or hazardous waste constituents, or changes Procedures <br /> the response necessary in an emergency; <br /> (d) The list of emergency coordinators changes; or § 1.4 - Plan <br /> Review and <br /> Update <br /> Procedures <br /> (e) The list of emergency equipment changes. § 1.4 - Plan <br /> Review and <br /> Update <br /> Procedures <br /> At all times, there must be at least one employee either on the Foreword - Certif. <br /> facility premises or on call (i.e., available to respond to an of QI and AQI, § <br /> emergency by reaching the facility within a short period of time) 4.2 - Qualified <br /> with the responsibility for coordinating all emergency response Individual, and <br /> measures. This emergency coordinator must be thoroughly Fig. 2.1 - Internal <br /> familiar with all aspects of the facility's contingency plan, all Notification <br /> operations and activities at the facility, the location and References <br /> characteristics of waste handled, the location of all records <br /> within the facility, and the facility layout. In addition, this person <br /> must have the authority to commit the resources needed to <br /> carry out the contingency plan. <br /> [Comment: The emergency Coordinator's responsibilities are more fully <br /> spelled out spelled out in 265.56.Applicable responsibilities for the <br /> emergency coordinator vary, depending on factors such as type and variety <br /> of waste(s)handled by the facility, and type and complexity of the facility.] <br /> (a) Whenever there is an imminent or actual emergency situation, §4.2 - Qualified <br /> the emergency coordinator(or his designee when the Individual <br /> emergency coordinator is on call) must immediately: <br /> (a)(1) Activate internal facility alarms or communication systems, §4.2 - Qualified <br /> where applicable, to notify all facility personnel; and Individual <br /> (a)(2) Notify appropriate State or local agencies with designated §4.2 - Qualified <br /> response roles if their help is needed. Individual <br /> Shell Supply and Distribution Cross Ref-8 Stockton Terminal FRP <br /> ©2019 Witt O' Brien's Revision Date:October, 2019 <br />