Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
STIMSON
>
2000
>
2900 - Site Mitigation Program
>
PR0009229
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/8/2026 9:39:55 AM
Creation date
6/26/2020 5:02:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0009229
PE
2960 - RWQCB LEAD AGENCY CLEAN UP SITE
FACILITY_ID
FA0004047
FACILITY_NAME
STOCKTON ARMY AVIATION SUPPORT FACILITY / PFAS SITE INSPECTION
STREET_NUMBER
2000
STREET_NAME
STIMSON
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
17726004 AND 17726034
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
2000 STIMSON ST STOCKTON 95206
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
399
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
If PID readings exceed 1,000 ppm in the OBZ for 15 minutes, Level B protection will <br />be required. Personnel must leave the Site immediately and contact the Site Safety <br />Officer or the Regional Health and Safety Manager for further instructions. <br />• Respirator cartridges will be changed a minimum of once per day. This can be <br />accomplished at the end of the work day during respirator decontamination. If odor <br />breakthrough is detected while wearing the respirator or breathing becomes difficult, <br />the cartridge will be changed immediately. <br />5.3 Action Levels/Level of Personal Protection Equipment (PPE) <br />PID <br />Instrument <br />Reading <br />LEVEL D <br />LEVEL C <br />LEVEL B/Reassess <br /><100 units for 15 <br />minutes <br />1,000 units for 15 <br />minutes <br />>1.000 units for 15 <br />minutes <br />5.4 PPE <br />Modified Level D is the minimum acceptable level for this Site. Modified Level D provides <br />minimal dermal protection. Respiratory protection is optional unless air monitoring data <br />indicates otherwise. <br />Modified Level D includes: <br />- coveralls/work uniform <br />- Tyvek (optional) <br />- Nitrile, butyl -rubber or Viton gloves with disposable nitrile liner (optional) <br />- boots/shoes, leather or chemical resistant, with steel shank and approved toe <br />protection <br />- approved safety glasses or chemical splash goggles if the potential for splash exists <br />- hard hat <br />- reflective traffic vest (if traffic, construction, or other related activities are present) <br />- hearing protection (as appropriate) <br />- respiratory protection (as necessary) <br />B. Additional equipment upgrade: <br />Protocols for upgrading <br />Once air monitoring data are complete and results are tabulated on the initial Site <br />entry, the Site Safety Officer and/or Regional Health and Safety Officer will <br />determine whether changes in PPE are needed. <br />3028-03/114700.4766.023/JUL-73'03 14 <br />