Laserfiche WebLink
, '!�q"c <br />Body Art InspectilbReport • <br />San Joaquin County Environmental Aalth Department <br />1868 E. Hazelton Ave., Stockton, GA 95205 <br />(209) 468-3420 <br />F Ra"P <br />wwwsioqv.org/ehd <br />PR Number <br />PRACTITIONERIARTIST NAME <br />PR0537490 <br />Christopher Flores <br />, PRO537640 <br />Fernando Hurtado <br />PRO540259 <br />Bryan Lares <br />PRO538099 <br />Mario Morales <br />Observations and Corrective Actions: <br />Date: 6 <br />Program <br />PRACTITIONER/ARTIST NAME <br />Record: <br />Michael Silva, AT 7/26/2020 <br />Program <br />Element: <br />t� <br />PR Number <br />PRACTITIONER/ARTIST NAME <br />PRO542483 <br />Michael Silva, AT 7/26/2020 <br />PR0536973 <br />Jose Zuniga, CM 2/2/2020 <br />4. Sterilizer shall be spore -tested after initial installation, after major repair, and at least once per month. A written sterilization <br />shall be maintained for 3 years. The log shall include spore -test results each sterilization cycle, date, contents, exposure time and <br />temperature, results of the Class V integrator for every cycle/load, and evidence of an acceptable spore test before reuse of the <br />sterilizer after a failed spore -test. HSC 119315(b) <br />Spore tests were not available at the time of the inspection. Do not use the autoclave until evidence of a recent <br />spore test is submitted to the EHD. Submit by 11/14/2019. <br />6. A facility that uses single use instruments shall maintain record of purchase, log of procedures, names of practitioner and <br />client, date of procedure, instruments used, and written evidence from the manufacture that the instruments have undergone <br />sterilization. The record of purchase, evidence of sterilization, type and number of instruments used shall be maintained for a <br />minimum of 90 days after use. HSC 119315(f) <br />Sterilization certificates were unavailable at the time of the inspection. Obtain by 11/14/2019. <br />9. No food, drink, tobacco product, or personal effects are permitted in the procedure area. HSC 119309 <br />A soda which was previously opened was sitting on the sink in the procedure area. <br />11. The procedure area shall be equipped with a sink with hot and cold running water, containerized liquid soap, and single use <br />paper towels dispensed from a wall -mounted, touchless dispenser that is readily accessible to practitioner. HSC 119314(b) <br />Two touchless paper towel dispensers and two soap dispensers require re -filling. Re -fill by 11/14/2019. <br />13. Practitioner shall provide evidence of a completed, EHD approved, OSHA Bloodborne Pathogen Training consistent with <br />section 119307. <br />Evidence of bloodborne pathogens training was not available for Christopher Flores, Bryan Lares, and Mario <br />Morales. Only Jose Zuniga and Michael Silva had posted current evidence of bloodborne pathogens training. <br />Obtain and post evidence of bloodborne pathogens training for all artists by 11/14/2019. <br />13. Practitioner shall provide evidence of a completed, EHD approved, OSHA Bloodborne Pathogen Training consistent with <br />section 119307. <br />No current artist permits posted for Jose Zuniga, Christopher Flores, Mario Morales, and Fernando Hurtado <br />(permit was present in shop). Post all artist permits by 11/14/2019. <br />Reinspecion on/about: A reinspection fee of $152 per hour may be charged. Page 2 of 3 <br />EH -11/17 <br />