ISOLATION ROOM CLEANING <br /> ,PROCEDURE FOR DECOMTAMATING EQUIPMENT THAT IS <br /> EXPOSED TO INFECTIOUS WASTE <br /> EQUIPMENT : <br /> Cleaning cloths , mop , 2 plastic buckets , 2 1 oz . measure , isolation <br /> gown, mask , cap , and gloves . <br /> CLEANING PRODUCTS : <br /> PREMKLEEN 18144 ounce per gallon of water <br /> PREMQUAT 900 2 ounce per gallon of water <br /> PROCEDURE : <br /> Housekeeping Personnel will wear isolation gowns , masks , caps , and <br /> gloves . <br /> Double bag anything removed from the unit . <br /> Remove and double bag cubicle curtains and drapes ® take to laundry <br /> for cleaning. <br /> Housekeeping Personnel will use a cloth soaked in PREMKLEEN 1814 <br /> solution to wash all articles in room including walls , ceiling, <br /> windows , door, and fixtures , and mop floor. <br /> Housekeeping Personnel will then use the PREMQUAT 900 solution to <br /> wash all articles and room parts with a clean cloth , and mop and <br /> rinse floor. <br /> FREQUENCY : <br /> Whenever isolation situation exists . <br /> SPECIAL CONSIDERATION : <br /> Isolation gowns , masks , gloves , caps , and cleaning cloths should <br /> be placed in a double plastic bag. Then taken to laundry to be washed. <br /> All soiled linen should be double bagged and taken to the laundry <br /> to wash . <br /> Water from contamination procedure should be poured down the laundry <br /> room sink. Buckets to be cleaned and rinsed in PREMQUAT 900 solution. <br /> RESPONSIBILITY : <br /> Commerical and Industrial Waste Removal will be called to pick <br /> up all waste products not laundered or cleaned. <br />