My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1994-2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
U
>
UNION
>
305
>
4400 - Solid Waste Program
>
PR0504176
>
COMPLIANCE INFO_1994-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 9:33:24 AM
Creation date
7/3/2020 10:34:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
1994-2017
RECORD_ID
PR0504176
PE
4430
FACILITY_ID
FA0006106
FACILITY_NAME
MANTECA CITY DUMP
STREET_NUMBER
305
Direction
N
STREET_NAME
UNION
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20015001
CURRENT_STATUS
01
SITE_LOCATION
305 N UNION RD
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\cfield
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4430_PR0504176_305 N UNION_1994-2017.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
134
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
County of Riverside <br /> <br /> 7 <br />(b) The design shall consider one or more proposed uses of the site toward which the <br />operator will direct its effect. <br /> <br />The installation of an 8.5 megawatt solar generating facility is the intended use of the site. The <br />site improvements have been designed to avoid penetrations to the cover and to minimize any <br />potential future damage associated with settlement. <br /> <br />(c) All post closure land uses, other than open space, on sites implementing closure or on <br />closed sites shall be submitted to the LEA, CalRecycle, RWQCB, local air district and <br />land use agencies. <br /> <br />This PCLUP has been prepared to meet the requirements of Title 27, Section 21190 and will be <br />submitted to the agencies having jurisdiction at the closed West Riverside Landfill. <br /> <br />(d) Construction on the site shall maintain the integrity of the final cover, drainage and <br />erosion control systems, and gas monitoring and control systems. <br /> <br />Construction of the proposed solar arrays will have a minimal effect on the existing cover <br />barriers as previously described. No penetrations of the cover are planned. <br /> <br />(e) Construction of structural improvements on top of landfilled areas during the post <br />closure period shall meet the following conditions: <br />(1) , (2), and (3) Automatic methane gas sensors, designed to trigger an audible alarm <br />when methane concentrations are detected, shall be installed in all buildings. <br /> <br />There are no buildings or basements associated with the solar array installations, therefore <br />accumulation of methane in buildings is not anticipated. <br /> <br />(4) and (5) Utilities shall be constructed to mitigate the effects of differential settlement. <br />All utilities shall be designed with flexible connections and utility collars. <br /> <br />Utilities associated with the solar arrays will be installed above the closure barriers with flexible <br />connectors to accommodate differential settlement. <br />(5) And (7) Piling shall not be installed in or through any bottom liner unless approved <br />by the RWQCB. Penetration through the low permeability layer of final cover must <br />be sealed and repaired. <br /> <br />No penetration of the final Landfill cover are proposed.
The URL can be used to link to this page
Your browser does not support the video tag.