Laserfiche WebLink
Page 9 �E 382- 063-00 <br /> each lot . Structural loads should be light to moderate . <br /> Reportedly, the building pads , approximately 60 feet by 60 feet , <br /> will be placed in the central portion of the lots . <br /> The composition and consistency of the subsurface materials <br /> are of overriding concern in this project. As indicated by our � <br /> investigation and substantiated by the history of the s.it.e , the <br /> near- surface materials consisting of miscellaneous debris <br /> intermixed with soil were placed in. a random, indiscriminate <br /> manner . Therefore , interpolation or extrapolation of the <br /> SU <br /> bsurface conditions, as revealed by our borings and test pitst. <br /> across the site are highly speculative and are not recommended. <br /> The potential for encountering isolated voids and areas of <br /> Ah <br /> organic matter exists at this site® <br /> Below the near- surface material , the principal soils <br /> found at this site are non-cohesive sandy silts and silty sands; <br /> thus, the action of foundations can be analyzed on the basis of <br /> the characteristics of granular soils . This type of soil <br /> generally has relatively high shearing values ; therefore, the <br /> bearing values for foundations placed on granular soils are <br /> usually based upon the allowable settlements of the proposed <br /> structures . The amount of soil settlement is directly related to <br /> the soil's relative density and the size and type of loading of <br /> the soil. <br /> Thi Foul dation Eiigirsers, hoc. <br />