COMPLIANCE INFO_1991-1997
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9069
>
4400 - Solid Waste Program
>
PR0440001
>
COMPLIANCE INFO_1991-1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/7/2021 10:53:56 AM
Creation date
7/3/2020 10:39:31 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
1991-1997
RECORD_ID
PR0440001
PE
4433
FACILITY_ID
FA0004514
FACILITY_NAME
AUSTIN ROAD/ FORWARD LANDFILL
STREET_NUMBER
9069
Direction
S
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
STOCKTON
Zip
95215
CURRENT_STATUS
02
SITE_LOCATION
9069 S AUSTIN RD
P_LOCATION
01
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sfrench
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440001_9069 S AUSTIN_1991-1996.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
700
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Stephen Chen MAR 0 6 1995 <br />Page 2 <br />scenario, it would appear that a substantial portion of the landfill will require partial <br />closure within two years. <br />3. Submit maps of the solid waste landfill to meet 14 CCR 18261.3(a)(1). The maps <br />submitted do not clearly showing the existing and proposed final limits of waste <br />placement in accordance with a closure implementation schedule. The map must <br />clearly show property boundaries, general location, all on-site structures, entry roads, <br />structures within 1000 -feet of the property, current monitoring and control systems, <br />total acreage, total acres permitted, and existing and proposed final limits of waste <br />placement. <br />4. All maps and drawings must be submitted as standard size (24" x 36") and include <br />translucent reproducibles (14 CCR 18268). <br />5. Provide testing information to justify the on-site borrow material sources. Otherwise, <br />general off-site borrow sources must be described. The final cover closure cost of <br />$2.75 per cubic yard (placement, grading, and compaction) appears too low, especially <br />if an offsite borrow source or bentonite additives are required. Please also note that <br />page 7 states that the final cover barrier layer will be clay compacted to a permeability <br />of 0.0000001 cm/sec or less (1 X 10'' cm/sec). <br />6. Does the final cover design address Subtitle D requirements? If geomembrane lined <br />cells are included, the minimum prescriptive final cover must include a geomembrane <br />component. Guidance for Subtitle D final cover design configurations is contained in: <br />U.S. EPA, November 1993, Solid Waste Disposal Facility Criteria Technical AVIanual, <br />EPA530-R-93-017, NTIS Publication PB94-100-450. State requirements under 14 <br />CCR Article 7.8 and 23 CCR Chapter 15 impose in addition to Subtitle D, a minimum <br />thickness of 1 -foot for the vegetative layer and a 2 -foot earthen or appropriate waste <br />layer acting as a foundation for the .final cover. Alternative final cover designs can be <br />proposed but must have adequate justification for approval in the Preliminary Plans. <br />7. Provide current descriptions of drainage controls and gas control measures. A current <br />description of all monitoring and control systems at the landfill must be submitted [14 <br />CCR 18261.3(a)(4)]. <br />8. The Preliminary Plans do not address gas control as required by 14 CCR 18261.3. <br />If gas control measures constructed during the operational life of the landfill will <br />address the closure standards of 14 CCR 17783, the Preliminary Plans should state so. <br />Otherwise, closure cost estimates must be included to provide for gas control measures <br />upon closure. <br />
The URL can be used to link to this page
Your browser does not support the video tag.