My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996-2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9069
>
4400 - Solid Waste Program
>
PR0440001
>
COMPLIANCE INFO_1996-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/7/2021 8:55:58 AM
Creation date
7/3/2020 10:39:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2003
RECORD_ID
PR0440001
PE
4433
FACILITY_ID
FA0004514
FACILITY_NAME
AUSTIN ROAD/ FORWARD LANDFILL
STREET_NUMBER
9069
Direction
S
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
STOCKTON
Zip
95215
CURRENT_STATUS
02
SITE_LOCATION
9069 S AUSTIN RD
P_LOCATION
01
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sfrench
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440001_9069 S AUSTIN_1996-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
623
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� 9 •_ t <br /> Monitoring Report Compliance Check-- <br /> Discharges <br /> heckDischarges Regulated by Title 27 and/or Part 258 <br /> R®N'QCB <br /> Reference Parameter Yes No N/A Reviewer Comment <br /> WDRs/MRP/ Groundwater Monitoring <br /> Standard <br /> Provisions 1. Are all groundwater Field Parameters X <br /> (Sept 93/Aug 97) Monitoring Parameter, and COCs <br /> (if required)samples and analyzed? <br /> in. Have any groundwater concentration X In wells: MW-1,MW-3, MW- <br /> limits been exceeded? If yes,identify 10,MW-11,MW-13, MW 14, <br /> in comments. 7898,and 8106. <br /> n. Is there a description and graphical X <br /> presentation of groundwater flow <br /> direction and gradient? <br /> o. Monitoring Wells: Is there a X <br /> description,method,and time <br /> of water level measurement and <br /> well recovery time? <br /> p. Purging: Is there a description X <br /> of the purging method,purge <br /> pump and its placement,and <br /> field parameters? <br /> Additional Comments and Recommendations: <br /> This site has an active groundwater treatment facility since 1994, as part of a corrective action program. The <br /> current treatment system has failed to contain or cleanup the contaminant plume. The discharger has begun <br /> work on a new corrective action plan to caj'ure the entire plume and clean up groundwater. Ownership at <br /> this site will be changing. <br /> Summary of wells exceeding groundwater concentration limits. <br /> Detection Monitoring Wells: MW-13, and MW-14—VOCs. <br /> Evaluation Monitoring Wells: MW-1, -10, and—11 —VOCs <br /> MW-1, -3, and—11 —one or more field or lab parameter. <br /> Private Wells: 7898, and 8106—VOCs. <br /> In the First Quarter 2000 there was a general failure of the run off control facilities and the leachate control <br /> facilities. Based on RWQCB and IWMB observations the extent of failure was under reported in the weekly <br /> standard observations reports. <br /> RWQCB Staff Signature: <br /> Date: <br />
The URL can be used to link to this page