Laserfiche WebLink
02-10-2000 04:10PM FROM TO 19162554216 P.01 <br /> Austin Road IandjUl EA ion Project EIR Comments and Responses ' <br /> $ ROM tp 9lif fa Rei ljatel 91i on B l�a� en�r�Valley R�gl'en ber <br /> 17.I999 Letter <br /> i <br /> ResPonse <br /> to Comment 1: The RWQCB previously reviewed and approved the design for the proposed <br /> landfill expansion when it issued Waste Discharge Requirements Order No.96-75. As described in that <br /> Order,the proposed landfill expansion would be lined and built to current standards. With respect to the <br /> existing landfill leachate issues, the regulatory oversight and associated mitigation of the Austin Road <br /> Landfill has been shared by the California integrated Waste Management Board and the Regional Water <br /> Quality Control Board. Both these boards have had an active part in assessing and stipulating <br /> requirements to address those areas of concern relating to the groundwater pollution generated by the <br /> existing landfill. in the last three to four years there have been a number of studies and mitigation <br /> measures completed to address both Boards' concerns. These are described in the DSEM pp. 96-99, <br /> The 1996 leachate discovery was mitigated, as approved by the RWQCB, with an interceptor trench to <br /> capture the leachate by November 19%. The leachate was collected in a 12,004-gallon storage tank and <br /> collected when near full for off-site treatment at a licensed TDS facility by Ramos Environmental, in <br /> 1997 after the.first reported detection of detectable PCE in the private wells, the City of Stockton <br /> committed to supplying bottled water to all downgradient well owners where there has been a detection of <br /> any VOCs above the drinking water standards. These wells are approximately 3,000 feet or more <br /> downgradient of the landfill boundary and are on a stipulated monitoring program. The City purchased <br /> one of the properties,removing the well from service,and continues to supply bottled water to the owners <br /> of the other private well. By October 1998, in response to the higher than permissible gas detection's <br /> reported in the northeastern part of the landfill,and with the approval of the Waste Management Board, <br /> the City installed and brought on-line an additional 12 vapor extraction wells to the existing gas collection <br /> system. The groundwater extraction and treatment system was also modified in 1998 to extract more <br /> contaminated groundwater. The lead regulatory agency overseeing the impact analyses and mitigation of <br /> the offsite contaminated groundwater-leachate-plume, the RWQCB, is currently in the process of <br /> reviewing the 1999 "Austin Road Landfill Groundwater Corrective Action Engineering Feasibility Study <br /> Report"to determine what additional augmentation of the groundwater extraction and treatment system is <br /> needed <br /> In order to assure consideration of this issue,the following is added to Mitigation K-6: <br /> "(b) The Cary of Stockton, San Joaquin County, RWQCB and IWMB should meet to determine if one or <br /> more of the existing landitil wets should be closed prior to approval of the expansion." <br /> 42 <br />