My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_1996_1
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9069
>
4400 - Solid Waste Program
>
PR0440001
>
ARCHIVED REPORTS_1996_1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:10 PM
Creation date
7/3/2020 10:40:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
1996_1
RECORD_ID
PR0440001
PE
4433
FACILITY_ID
FA0004514
FACILITY_NAME
AUSTIN ROAD/ FORWARD LANDFILL
STREET_NUMBER
9069
Direction
S
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
STOCKTON
Zip
95215
CURRENT_STATUS
02
SITE_LOCATION
9069 S AUSTIN RD
P_LOCATION
01
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440001_9069 S AUSTIN_1996_1.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
460
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 2-SITE OPERATIONS PLAN Page 2-14 <br /> Figure 2-3 <br /> NSWMA SAFETY CHECKLIST <br /> f3tJILDINCa.ECFTS;(OSI(A:191033-191x;37)'' . FIRES)MNGUISHER:EQUPMENT(OM4A 1910119T}::.: <br /> -1. Doors swing win exit savei _30. Extinguishers are inspectea monthly for pnysical carnage <br /> _2. Marked with lighted signs 31. Inspection records are kept indicating inspector <br /> ®3. Not locket so that may may be usea`rom the inside at all times ®32. Maintenance performed yearly;hydrotested every 5 years,if <br /> required <br /> _4. Keep free of obstructions __33. Inspection tags marked by month and year <br /> __5. Non-exit coors which can be mistaken as an exit are marked as"No 34. Extinguishers conspicuously installed and properly marked <br /> Exit for use by type of fire(A,B,C and D) <br /> ®6. S:rgle exits are a:!owed for rooms co^taining less than 25 people 85. The top of portable extinguishers(less than 40 lbs)mounted <br /> no more than 5 feet above the floor <br /> COMBUSTI8LE;.OXIDMNG;AND FLAMMABLE AGENTS,Whea using X36. The top of portable extinguishers(40 lbs or mare)mounted <br /> (OSHA 19QFx1 191x18} no more than 3.5 feet above the floor <br /> _.,...,,._ .. <br /> -7. E:ec:ncai installa.on ano static eiectray are controllea or maintainerFtF A10 ; <br /> 9 P 37 An approved first aid kit is available <br /> �8. Heatin appliances are controlled or maintained in a safe manner <br /> ®9. "Hot'work(weld!rg)co^.rolled or maintained in a safe manner 38. Emergency numbers of tympany-approved dors and <br /> hospitals posted in appropriate locations <br /> _10. At least one 20-pound Class D fire ex nguisher is within 25 feet of a _39. Trained personnel available <br /> storage area <br /> _11. ICC-approved metal drums are used'of storage from 5 to 60 gallons :HANI3 AND.PaRFABC.£.TOOLS(C9tEA:191II241-28s634� <br /> ®12. Not more than requires for 1 day or s,-'hs stored outside storage ®40. All useable toois have guards property instailea <br /> cabinet <br /> CDG9RRESS'-0 AtID.'UQUIFIED:GASES:(OSHA 1910*10.1-1.91A T16): 41. All portable electrical tools are tested monthly for ground <br /> ... <br /> _13. Charged and emoy cyi.noers are separates 42. Records kept of inspection(Item 41) <br /> ®14. Cylinders are grouped cy type and stored in vertical positions _43. All tools in safe operating condition and are free from worn <br /> or detective parts <br /> ®15. Cylinders are not stores rear other combustible material 44. Jacks and hoists are legibly marked with the!oad rating <br /> �16. Cylinders are supporter so that they cannot be tipped over - HOUS... <br /> ®17. Cylinder caps are in place on all cylincers that are not in use ®45 Materials on wailsishelves stored in a safe ano oroerty <br /> mariner <br /> 18. Oxygen cylinders are not stored within 20 feet of other types of gases 46. Facility is in a clean,orderly,and sanitary condition <br /> NAPE ®47. Hoses,welding leads,drop lights,etc.,are roiled and <br /> .... Properly stored <br /> .. <br /> ®19. Drains are ventec:o prevent collection of combustible gases 48. Permanent aisles and passageways are free of obstructions <br /> _20. Grease and oil prevented from entering public sewage systems 49. Permanent aisles and passageways are permanently <br /> marked <br /> E1EC7RIGAL;EQUIPMEt1f (Q$tEA t9tQ 308"1910:309) ILL13(NENA710IK :>::»:::>::. . <br /> ®21. A;l outlet and junc:on boxes are properly covered 50. Sufficient quantity(20 foot-cantles or greater) <br /> -22. All portable elec=cal tools and appliances are properly grounded ®51. Uniform distribution <br /> _23. Records maintained for inspection of portable electrical tools and _52. Well directed <br /> appliances <br /> _24. E:ectrical cabinet doors with exposed conductors of 50 volts or moreINDUTRIALSkN> ATEON.(C;3FFA, SiO <br /> are secure fastened <br /> e ed <br /> _25. Enc:osures around high-voltage elect cai equipment are marked _53. Clears,availaoie drinking fountains <br /> ...26. Frayed cords,cables,and loose wires regularly removed from service ®54. Facilities are maintained in a clean and stocked condition <br /> 27. Switch boxes are identified as to equipment they control _55. Hot water available <br /> Ef1ERGEtJCY:,fICH7iNG; _58. Individual towels and drinking carps available <br /> __28. Exits anc necessary ways to exits are:,;uminatec _57. Toilet facilities are within 200 feet of working a ea for each <br /> sex <br /> _29. Exit signs are illumina:ec to at leas.5'rot candles INDUSTR(ALTRUCK...FORKLIFT:;(OSHA:9:910,I78f <br /> : _::.....:.... :.:. <br /> _58. Brakes in goon operating condition <br /> _59. Guard behind fork is in place(to guard from load falling to <br /> the rear) <br /> _60. Load capacity of truck marked <br /> 61. No one except operator permitted fo ride <br /> _62. No one stands or walks under raised forks <br /> e63. Overhead guard to protect against falling objeca <br /> R.W.Sac t arc Assoc:a:as C;-,y of Stockton <br /> 1811.0.^,2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.