Laserfiche WebLink
RDSI SECTION <br />REG. CITATION <br />RESPONSE <br />REFERENCE <br />It is recommended that a geotechnical analysis be conducted <br />to determine if liquefaction conditions exist in the landfill <br />subgrade. <br />111.6.4. Settlement Analysis <br />14 CCR 17776 <br />The Austin Road Landfill Expansion Landfill Settlement <br />Appendix E, <br />Analysis letter report discusses landfill settlement and includes <br />Landfill Settlement <br />settlement calculations for final closure settlement, vertical <br />Analysis <br />expansion liner settlement, and horizontal expansion liner <br />settlement. It is recommended that additional geotechnical <br />investigation work be conducted prior to the final design of the <br />vertical expansion to define the compaction characteristics <br />and variability of the existing refuse fill. It is also <br />recommended that additional geotechnical investigation and <br />analysis be conducted to determine the settlement <br />characteristics of the horizontal expansion subgrade. <br />III.B.5. Leachate Generation <br />Leachate generation estimated using HELP model, see FDSR <br />Appendix I, FDSR <br />Appendix B "HELP Model and Leachate Generation <br />Appendix B <br />Quantities". <br />III.B.6. Drainage System <br />See FDSR Appendix D "Stormwater Detention Calculations" <br />Appendix 1, FDSR <br />Capacity Requirements <br />for detention pond sizing calculations and ditch capacity <br />Appendix D <br />calculations. See RDSI Appendix L for creek relocation <br />Appendix L <br />design. <br />III.B.7. Gas Generation and Air <br />The Austin Road Landfill Expansion Landfill Gas Generation <br />Appendix F, Landfill <br />Emission Calculations <br />Analysis letter report discusses gas generation and projected <br />Gas Generation <br />emissions. <br />Analysis <br />III.B.8. Soil Erosion Analysis <br />14 CCR 17779 <br />See FDSR Section 1.5.7 and FDSR Appendix C "Universal <br />Appendix I, F <br />Soil Loss Equation Calculations". <br />Appendix C <br />LV. DISPOSAL SITE IMPROVEMENTS <br />14 CCR 17656 <br />Identification and entry signs are posted at the facility <br />Appendix I, FDSR <br />(Identification Signs) <br />entrance. <br />Sec. 2.1.2, Page 2-2 <br />14 CCR 17657 (Entrance <br />Final Grading Plan (P1) shows: <br />Appendix B, <br />Signs) <br />CEP Dwg. P1, <br />14 CCR 17658 (Site <br />- Locations of scale facilities, entrance facilities and facilities <br />CEP Dwg. P7, <br />Security) <br />equipment area. <br />Details 5, 6, 7, 10 <br />14 CCR 17659 (Access <br />- Site security fencing and gated access points. No public <br />Roads <br />access to site. <br />14 CCR 17660 (Internal <br />