COLUMBIA ANALYTICAL SERVICES, INC. <br />Client: Shaw Environmental & Infrastructure, Inc. Service Request No.: P0700704 <br />Project: Foothill Landfill, San Joaquin County (New Wells) Date Received: 8/2/07 <br />Sample Matrix: Water <br />CASE NARRATIVE <br />All analyses were performed consistent with the quality assurance program of Columbia Analytical Services, Inc. <br />(CAS). This report contains analytical results for samples designated for Tier II data deliverables. When appropriate to <br />the method, method blank results have been reported with each analytical test. Surrogate recoveries have been reported <br />for all applicable organic analyses. Additional quality control analyses reported herein include: Matrix/Duplicate <br />Matrix Spike (MS/DMS), and Laboratory Control Sample (LCS). <br />Sample Receipt <br />Two water samples were received for analysis at Columbia Analytical Services, Kelso on 8/2/07. The samples were <br />received in good condition and consistent with the accompanying chain of custody form. The samples were stored <br />in a refrigerator at 4°C upon receipt at the laboratory. <br />General Chemistry Parameters <br />No anomalies associated with the analysis of these samples were observed. <br />Total and Dissolved Metals <br />No anomalies associated with the analysis of these samples were observed. <br />Organochlorine Pesticides by EPA Method 8081A <br />Continuing Calibration Verification (CCV) Exceptions: <br />The primary evaluation criterion was exceeded for Toxaphene in the CCV. In accordance with CAS standard <br />operating procedures, the alternative evaluation specified in the EPA method was performed using the average <br />percent recovery of all analytes in the verification standard. The standard meets the alternative evaluation criteria. <br />Results for Toxaphene in QC sample KWG0708498-1 LCS/2DLCS have been reported from a column using average <br />percent recovery of all analytes in the verification standard. <br />No other anomalies associated with the analysis of these samples were observed. <br />PCB Aroclors by EPA Method 8082 <br />No anomalies associated with the analysis of these samples were observed. <br />Herbicides by EPA Method 8151A <br />Continuing Calibration Verification (CCV) Exceptions: <br />The analysis of Chlorinated Herbicides by EPA 8151 requires the use of dual column confirmation. When the CCV <br />criteria is met for both columns, the higher of the two sample results is generally reported. The primary evaluation <br />criteria were not met on the confirmation column for MCPP. The results are reported from the column with an <br />acceptable CCV. The data quality is not affected. No further corrective action was necessary. <br />Approved by f�.�s 36 Datciq <br />t <br />