As-Built CQA Report for the Construction of Area 2A at the Foothill Sanitary Landfill <br /> San Joaquin County,California <br /> compaction was based on ASTM D1557. Field density tests using a nuclear gauge (ASTM D6938) <br /> were taken at a frequency of one test for every 1,500 cubic yards, and sand cone (ASTM D1556) <br /> tests were taken at a frequency of one test per 4 nuclear density tests. When field density tests <br /> showed failing results, the area represented by the failed test was either reworked and <br /> recompacted or the failing materials were removed and replaced with properly compacted fill. <br /> A summary of CQA test results for earthfill is presented in Table 1. Laboratory test data sheets are <br /> included in Appendix E.1. The approximate test locations are shown in Figure 5. <br /> The results of field density tests for earthfill,as summarized in Table 1,indicate the following: <br /> ■ The in-place dry density of the compacted earthfill materials (passing tests) had an <br /> average dry density of 95.8 pounds per cubic feet (pcf). The relative compaction ranged <br /> from 90 to 100 percent with an average of 93.9 percent. The required minimum relative <br /> compaction was 90 percent based on ASTM D1557. <br /> ■ The in-place dry density of the compacted earthfill in the upper 2.5 feet of the roadway <br /> section had an average dry density of 106.4 pounds per cubic feet (pcf). The relative <br /> compaction ranged from 95 to 100 percent with an average of 97.9 percent. The required <br /> minimum relative compaction was 95 percent based on ASTM D1557. <br /> • ■ The in-place moisture content of earthfill materials ranged between -1.8 and +4.2 percent <br /> with an average of+1.7 percent of optimum based on ASTM D1557. <br /> PA14 Projects114-101(SJCDPW North County and Foothill)IFoothill CQA1Report\Final ReportToothill CQA Rport-Final.docx <br /> 10 <br />