My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WAVERLY
>
6484
>
4400 - Solid Waste Program
>
PR0440004
>
ARCHIVED REPORTS
>
ARCHIVED REPORTS_2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:49 PM
Creation date
7/3/2020 10:46:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2015
RECORD_ID
PR0440004
PE
4433
FACILITY_ID
FA0004517
FACILITY_NAME
FOOTHILL LANDFILL
STREET_NUMBER
6484
Direction
N
STREET_NAME
WAVERLY
STREET_TYPE
RD
City
LINDEN
Zip
95236
APN
09344002
CURRENT_STATUS
01
SITE_LOCATION
6484 N WAVERLY RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440004_6484 N WAVERLY_2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
724
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
As-Built CQA Report for the Construction of Area 2A at the Foothill Sanitary Landfill <br /> San Joaquin County,California <br /> compaction was based on ASTM D1557. Field density tests using a nuclear gauge (ASTM D6938) <br /> were taken at a frequency of one test for every 1,500 cubic yards, and sand cone (ASTM D1556) <br /> tests were taken at a frequency of one test per 4 nuclear density tests. When field density tests <br /> showed failing results, the area represented by the failed test was either reworked and <br /> recompacted or the failing materials were removed and replaced with properly compacted fill. <br /> A summary of CQA test results for earthfill is presented in Table 1. Laboratory test data sheets are <br /> included in Appendix E.1. The approximate test locations are shown in Figure 5. <br /> The results of field density tests for earthfill,as summarized in Table 1,indicate the following: <br /> ■ The in-place dry density of the compacted earthfill materials (passing tests) had an <br /> average dry density of 95.8 pounds per cubic feet (pcf). The relative compaction ranged <br /> from 90 to 100 percent with an average of 93.9 percent. The required minimum relative <br /> compaction was 90 percent based on ASTM D1557. <br /> ■ The in-place dry density of the compacted earthfill in the upper 2.5 feet of the roadway <br /> section had an average dry density of 106.4 pounds per cubic feet (pcf). The relative <br /> compaction ranged from 95 to 100 percent with an average of 97.9 percent. The required <br /> minimum relative compaction was 95 percent based on ASTM D1557. <br /> • ■ The in-place moisture content of earthfill materials ranged between -1.8 and +4.2 percent <br /> with an average of+1.7 percent of optimum based on ASTM D1557. <br /> PA14 Projects114-101(SJCDPW North County and Foothill)IFoothill CQA1Report\Final ReportToothill CQA Rport-Final.docx <br /> 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.