My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2002_1
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2002_1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:24 PM
Creation date
7/3/2020 10:48:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2002_1
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2002_1.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
105
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• If a surface inlet is blocked with debris, all necessary labor forces and <br /> equipment will be implemented under the direction of the operator to <br /> remove the blockage. <br /> • If a storm drain is damaged, a plan will be provided by the Site Engineer <br /> to repair the problem. <br /> • After the drainage problem is corrected, an assessment of possible <br /> damage or erosion will be conducted and all necessary repairs will be <br /> made to meet the 100-year/24-hour storm event, the design standard for <br /> the drainage facilities established at closure. <br /> 5.9 VANDALISM <br /> The following procedures will be followed during incidents of vandalism: <br /> • Repair (i.e., replace, repaint) any portion of the property which has been <br /> vandalized. <br /> • Immediately repair any vandalism, which affects site security and/or <br /> environmental control/monitoring systems. <br /> • A review of the adequacy of site security after each incident shall be <br /> performed. <br /> 5.10 UNDERGROUND FIRES <br /> Underground landfill fires occur due to air intrusion and moisture into the <br /> refuse cell. Indicators of underground fires are as follows: <br /> • Unusual depression-like settlement with tension cracks. <br /> • Smoke/steam. <br /> • Unusual odor. <br /> • Gas monitoring probe readings. <br /> Should any of the above indicators be noted, the first course of action should <br /> be placement of soil to cover the depression and/or cracks. If this measure <br /> does not correct the problem, additional measures may be taken under the <br /> direction of the SSO. <br /> 5.11 EMERGENCY RESPONSE PLAN ORIENTATION <br /> Contacts should be made with appropriate emergency response agency <br /> Forward Landfill FPCPCMP 5-5 <br /> Z:\PROJECTSWIIied Waste\Forward\Reference Files Prior JTDWune 05 Stage IA Partial FCPCMP\FL-sec 5.doc:6/16/2008 <br />