My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2006_20
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2006_20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:25 PM
Creation date
7/3/2020 10:51:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2006_20
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2006_20.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ms. Christina Carbajal <br /> April, 24, 2006 <br /> Page 4 <br /> SCS will continue to monitor and adjust all LFG extraction wells to minimize the amount of <br /> overpull while maintaining operational criteria. <br /> Also, on March 28,2006, SCS performed initial monitoring/adjustment to, recently installed by <br /> others,LFG Extraction.Well.Nos. FOFU-0304- Well, FOFU-04-06 through FOFU-04-12, FOFU- <br /> HCO1, FOFU-04-LCR,FOFU-05-06 and FOFU-OSHCI in.attempts to help decrease the observed <br /> elevated methane gas concentrations detected at GP-11 and GP-12 as directed by the client. SCS <br /> will continue to adjust wells as directed by Allied personnel.. <br /> Finally, during this reporting period,temperatures at LFG extraction wells were monitored and <br /> observed to range from 51 to 93 degrees Fahrenheit(see Table 3). These temperatures are <br /> considered to be in the low to normal range for anaerobic decomposition. SCS will continue to <br /> test LFG temperatures at each extraction well on a monthly basis in order to develop a database. <br /> This additional infoTmati.on should provide a better understanding of subsurface conditions at the <br /> site: - <br /> LFG Collection Systexn <br /> Visual observation of the LFG collection system.is conducted twice per month. During these <br /> visits, observations are made to ensure no pipe breakages have occurred and condensate drain <br /> sumps remain functional. Minor.repairs are completed as required. <br /> On March 8, 13, 21 and 27, 2006, SCS performed monitoring of all accessible LFG condensate <br /> 5u11Z.ps defined as ARTP-1 through 7 and FOTP-8 through 19 and recorded the liquid level control <br /> pump cycle counters (see Table 3)_ <br /> In addition, during pervious reporting periods, SCS observed and repaired several slight air supply <br /> and/or liquid leaks at several LFG condensate sumps. As requested by the Client, SCS has <br /> prepared a proposal dated August S, 2004,and recommends that the existing air and <br /> condensate connections he modified to decrease the potential for future separations/air leaks. <br /> Finally, SCS routinely conducts a pressure drop survey(Le., measurement of main pipeline <br /> pressure at various points throughout the LFG collection system). The results of this survey <br /> indicated that no major restrictions within the LFG collection system currently exist and all <br /> accessible extraction wells are receiving adequate vacuum. <br /> LFG Blower/Flare Station (BFS) <br /> Visual observations and testing of the LFG BFS was conducted on March 4. 8, 21, 22,23,27, 29 <br /> and 30. 2006. During these visits, operating parameters Axe zn.onitored and mechanical and <br /> electrical components are checked for workability. Throughout the.reporting period,the BFS was <br /> set to operate continuously. BFS data is shown in Table 4. <br />
The URL can be used to link to this page
Your browser does not support the video tag.