Laserfiche WebLink
Ms. Christina Carbajal <br /> April 24,2006 <br /> Page 5 <br /> SCS understands the BFS operated as programmed throughout the reporting period with.the <br /> exception of the foll.owin.g scheduled and unscheduled shutdowns: <br /> • On March 22, 23, 29 and 30, SCS was notified by the Automatic Dialer System (ADS) <br /> of a BFS shutdown. Upon arrival, SCS observed the shutdowns were attributed to a <br /> high exhaust gas temperature. On each occasion, the BFS was restarted., flow and <br /> temperature controller adjusted and normal operation verified. <br /> • On March 26, 20065 SCS was notified by the ADS of a BFS power failure shutdown. <br /> Upon arrival the following day, SCS reset necessary controls,restarted the BFS and <br /> verified proper operation. <br /> On March 8,20064 SCS performed monthly BFS Condensate Storage Tank Carbon Vent VOC <br /> breakthrough testing. Photo Ionization.Detector. (PID) results indicated that no VOC's were <br /> detected at the inlet and outlet of the carbon,vent. <br /> Also, on March 29, 2006, SCS performed Hydrogen Sulfide (H2S)monitoring of the BFS as <br /> required by the SJVAPCD. Results of this testing indicated that 3 parts per million (pprn)I12S was <br /> detected. The next required quarterly testing is to be performed by the month of June 2006. <br /> Tn addition,as previously reported, SCS observed several areas of paint on.the upper portion of the <br /> flare stack, which have begun.to discolor and/or flake off the exterior surface. SCS will continue <br /> to inspect these areas and make further recommendations as necessary_ <br /> Finally, during the reporting period, the flare exit gas temperature was observed to remain above <br /> the SJVAPCD 1400 degree Fahrenheit prescribed operating criteria. The lowest flare exit gas <br /> temperature observed by SCS during our site visits was approximately 1593 degrees Fahrenheit. <br /> All other operating parameters remained within acceptable operating limits. <br /> Site Surface Obsen ation <br /> Visual observation of the landfill surface along the extent of the extraction system is also <br /> performed on a monthly basis. Observations for erosion, surface cracks (that might allow LFG to <br /> escape or promote air intrusion)and settlement around,wells, laterals and main pipelines are <br /> conducted. <br /> During this reporting period, no settlement that might adversely impact (e.g., allow Condensate <br /> accumulation such that a complete blockage could occur)the LFG collection system operation was <br /> observed,with the exception of the previously mentioned area of flooding on the Austin section <br /> side of the landfill. <br />