FOURTH QUARTER 2007 GROUNDWATER TREATMENT FACILITY MONITORING REPORT <br /> FORWARD LANDFILL WDR ORDER NO.R5-2003-0080 <br /> During a site visit on October 16,2007,a field technician attempted to measure the depth to <br /> water in EW-2.The technician determined that the depth to water was greater than 107 feet <br /> below the top of the well casing(btoc)when the pump was running.The technician was <br /> unable to measure the depth to water because of an obstruction at 107 feet btoc.The top of <br /> the pump is located more than 110 feet btoc.The technician turned off EW-2 and allowed <br /> the well to recharge for 1 hour,and then measured a depth to water of 67 feet btoc.The <br /> technician then turned on EW-2,and the depth to water increased from 67 feet btoc to more <br /> than 107 feet btoc in several seconds.Operation of the pump appeared to rapidly draw <br /> down the water table surface to the pump intake.The technician throttled the globe valve <br /> located at the wellhead to slightly restrict the well flow rate and reduce the chance of pump <br /> cavitation.The globe valve was throttled until the maximum safe operating pressure of the <br /> upstream piping(100 pounds per square inch)was reached. <br /> During first quarter 2008,CH2M HILL will evaluate operation of EW-2 and determine if <br /> additional field measurements are required.CI-12M HILL will also evaluate whether <br /> redevelopment of EW-2 and repair or replacement of the submersible pump are necessary. <br /> Results of the evaluation will be discussed in the First Quarter 2008 Groundwater Treatment <br /> Facility Monitoring Report. <br /> An electrician visited the GTF on November 19,2007,to troubleshoot the plant flow meters. <br /> The electrician determined that the GTF main plant flow meter program parameters had <br /> reset to the default values and,therefore,both the instantaneous flow rate and the totalized <br /> flow were being computed improperly. It is believed that the program parameters reset <br /> between October 2 and 16,2007.The electrician successfully reprogrammed the GTF main <br /> plant flow meter.The electrician then recalibrated each extraction well flow meter <br /> individually against the GTF main plant flow meter.After calibration,the GTF,EW-1,and <br /> EW-2 continued operating. <br /> During fourth quarter 2007,the GTF shut down four times because of power outages on <br /> October 12,November 4,December 7,and December 16.The GTF was restarted following <br /> each power outage on October 12,November 5,December 7, and December 18,respectively. <br /> 3.0 Influent and Effluent Monitoring <br /> Under WDR Order No. R5-2003-0080,effluent samples are analyzed as follows: <br /> • Monthly for pH,specific conductivity,and VOCs <br /> • Quarterly for total dissolved solids <br /> • Annually for dissolved inorganics <br /> All parameters were analyzed during fourth quarter 2007. Figure 1 shows the effluent <br /> monitoring location.Table 2 presents the results of the effluent monitoring performed <br /> during fourth quarter 2007. Appendix A contains the effluent monitoring field sampling <br /> logs and laboratory results for fourth quarter 2007. <br /> The current WDRs stipulate that the concentration limit for VOCs in the effluent is non- <br /> detect. No VOCs were detected in the GTF effluent samples collected during fourth <br /> quarter 2007. <br /> RDD/0111 10101(NLH3684.DOC) 2 <br />