ARCHIVED REPORTS_2007_17
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2007_17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:25 PM
Creation date
7/3/2020 10:52:47 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2007_17
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2007_17.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3.0 SUMMARY AND CONCLUSIONS <br /> The test program described herein was successful, in achieving the goal of <br /> developing in-place density information for the selected ADC materials. The <br /> authors feel that this program could be duplicated at other sites, and that the results <br /> yielded could be repeated within a reasonably small range. <br /> Thickness measurements require some judgment to determine just where cover <br /> stops and MSW starts, due to the heterogeneous nature of MSW and the somewhat <br /> rough surface to which the ADC is applied. It should also be noted that California <br /> standards for the application of greenwaste ADC call for an average thickness of <br /> between 6" and 12". Both test plots constructed with greenwaste resulted in > 12" <br /> average thickness. <br /> A summary of the test results are presented below: <br /> Shredded greenwaste density had a range of 110.3 Ib/cy, an average of <br /> 776.3 Ib/cy, a standard deviation of 78.0 Ib/cy and a coefficient of variation <br /> of 10.05%. A possible explanation for this variation is that since the lower <br /> result was produced on the sloped test plot, the shredded greenwaste <br /> compacts less readily on a slope than it does on a flat deck. <br /> TASW density had a range of 88.6 Ib/cy, an average of 1,124.8 Ib/cy, a <br /> standard deviation of 62.65 Ib/cy, and a coefficient of variation of 5.57%. <br /> These measures indicate that placement and compaction of TASW was very <br /> consistent during this test program. While TASW showed higher density on <br /> the sloped test plot, no conclusion should be drawn without further testing <br /> and a larger statistical population. <br /> The results from the ADC Test Program conducted on October 11 and 12, 2006, <br /> provide the necessary data to finalize the JTD Amendment. Allied and BAS are <br /> ready to meet with the LEA to integrate the results of this ADC field testing into a <br /> Joint Technical Document (JTD) Amendment. Allied will then prepare and submit <br /> the JTD Amendment to comply with 27 CCR and reconcile LEA concerns with ADC <br /> usage at the FL. <br /> 3-1 <br /> J:\A11ied\Forward\2006.0154 ADC Test\ADC Test Report\Final ADC Test Report Sec 3.doc <br />