ARCHIVED REPORTS_2012_3
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2012_3
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:42 PM
Creation date
7/3/2020 10:56:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2012_3
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2012_3.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
165
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The lysimeters were checked for soil-pore liquid on May 7, 2012, and Del-Tech reported <br /> that all lysimeters were dry. However, lysimeters LY-E 1 B, LY-E2B, D-93B, WMU- <br /> DOl, WMW-D02, WMU-D02 (pan), and FU-03 could not be located or are damaged, <br /> while lysimeters LY-ElA and LY-E2A were reported to be plugged. <br /> Samples were collected by Del-Tech from each sample point containing sufficient liquid <br /> and submitted to BC Laboratories(BC) of Bakersfield, California, a state certified <br /> laboratory under contract to Forward. During the second quarter 2012 monitoring period, <br /> samples were analyzed for the routine monitoring parameters stipulated in RWQCB <br /> Order No. R5-2003-0049. Table 2-1 summarizes site monitoring parameters, analytical <br /> methods, and monitoring frequency. Water quality samples were also analyzed in the <br /> field for oxygen reduction potential (ORP), turbidity, temperature, specific conductance, <br /> and pH and recorded on well data sheets. The groundwater monitoring wells and <br /> leachate monitoring points were sampled in accordance with the sampling and analysis <br /> procedures detailed in Appendix B. The well data sheets, laboratory data, certificates of <br /> analyses, and chain-of-custody records for the sampling program are included in <br /> Appendix C. The laboratory analyses and field results for groundwater monitoring wells, <br /> surface water stations, lysimeter and leachate sampling stations are summarized in Tables <br /> 2-2 through 2-6. <br /> 2.1.2 QA/QC Results <br /> The quality assurance/quality control (QA/QC)program completed for the second quarter <br /> 2012 water quality monitoring event included analyses of one field blank, one trip blank, <br /> two laboratory method blanks, and one duplicate sample. The field and trip blanks were <br /> analyzed for volatile organic compounds (VOCs) by EPA Method 8260 and method <br /> blanks were analyzed for all of the analytes included in the monitoring program. The <br /> results of the QA/QC program indicate that no VOCs were detected in the QA/QC blanks <br /> during the monitoring period. During the second quarter 2012 monitoring event, a <br /> duplicate sample was collected from wells MW-19 and labeled FMW-Duplicate. The <br /> duplicate sample analyses yielded good correlation (less than 3%relative percent <br /> difference). Review of second quarter 2012 sampling dates and laboratory analytical <br /> certificates indicates that all of the laboratory analyses were completed within required <br /> holding times. Based on the results of the laboratory QA/QC analyses, it is concluded <br /> that the laboratory data generated for the second quarter 2012 monitoring period are <br /> generally acceptable and the water quality samples collected from the Forward Unit <br /> appear to be representative of water quality at the site. <br /> 2.1.3 Groundwater Elevations and Contours <br /> Prior to purging and sampling, each well was sounded for water depth using a weighted <br /> electronic sounder to an accuracy of 0.01 foot, and the static water level was recorded on <br /> a Well Data Sheet (Appendix Q. The groundwater elevations were calculated for each <br /> well by subtracting the depth-to-water measurement from the top-of-casing reference <br /> elevation. The current groundwater elevation data for the Forward Unit is summarized in <br /> Table 2-3. <br /> C:\2012-0023\FA 2Q12.doc 4 Geo-Logic Associates <br />