Laserfiche WebLink
wide, with the weld centered along the length of the sample. The sample must be divided into three <br />sections: one 12 -inch by 12 -inch section for the Geosynthetics Contractor, one 12 -inch by 18 -inch <br />section for laboratory testing, and one 12 -inch by 12 -inch for the Owner to archive. Record the <br />results of field testing on the destructive seam tests form, the panel/seam log. <br />Third Party Laboratory Testing. All CQA destructive samples must be shipped to the <br />testing laboratory to verify seam quality. The laboratory will test five specimens from <br />each sample in each method used. Minimum test values are presented in the <br />specifications. The testing laboratory must provide test results within 24 hours, in <br />writing or via telephone, to the QA/QC Manager with certified test results to be provided <br />within 5 days. <br />The QA/QC Manager must immediately notify the Construction Manager and Geosynthetics <br />Contractor in the event of failed test results. <br />If the laboratory test fails in either peel or shear, the Geosynthetics Contractor must either reconstruct <br />the entire seam, or recover additional samples at least 10 feet on either side of the failed sample for <br />retesting. This process is repeated until passed tests bracket the failed seam section. All seams must <br />be bounded by locations from which passing laboratory tests have been taken. Laboratory testing <br />governs seam acceptance. In no case can field testing of repaired seams be used for final acceptance. <br />4.2.5 Repairs <br />Portions of geomembrane panels and seams that: (1) contain a flaw; (2) a destructive test; or (3) <br />nondestructive test cuts of holes, must be repaired in accordance with the Specifications. The <br />QA/QC Inspector must locate and record all repairs on the repair sheet and panel layout drawing. <br />Acceptable repair techniques include the following: <br />• Patching -used to repair large holes, tears, large panel defects, undispersed raw materials, <br />welds, contamination by foreign matter, and destructive sample locations. <br />• Extrusion - used to repair small defects in the panels and seams. In general, this <br />procedure should be used for defects less than FI -inch in the largest dimension. <br />• Capping - used to repair failed welds or to cover seams where welds cannot be <br />nondestructively tested. <br />• Removal - used to replace area with large defects where preceding methods are not <br />appropriate. Also used to remove excess material (wrinkles, fishmouths, intersections, <br />etc.) from the installed geomembrane. Areas of removal shall be patched or capped. <br />Repair procedures include the following: <br />• Abrade geomembrane surfaces to be repaired (extrusion welds only) no more than 1 hour <br />0 Page 35 <br />